GE JSP26 Скачать руководство пользователя страница 6

6

Installation Instructions

6

ELECTRICAL CONNECTIONS

TO MAKE ELECTRICAL CONNECTION 

Remove the junction block access cover 
(on range back). See Fig. 12A or 12B. 

SOME MODELS

will have a one-piece wire

cover shown in Fig. 12B. When re-installing
one-piece wire cover, make sure that wire
does not become pinched between wire
cover and mainback. 

All new constructions, mobile homes,
recreational vehicle and installations where
local codes do not allow grounding through
neutral, require a four-wire flexible cord kit.
If the range is rated between 8,750 and
16,500 watts, a range cord kit rated for 
40 amps and a minimum of 125/250 Volts 
is required. If the range is rated between
16,501 and 22,500 watts, a range cord kit
rated for 50 amps and a minimum of
125/250 Volts is required. For existing
construction, a three wire flexible cord kit
may be used, and the same ratings apply 
as described above. 

When using a cord rated 40 Amps, remove
the next to outermost knockout (1-3/8

diameter) in the connection plate. Likewise,
when using a cord rated 50 Amps, remove
the outermost knockout (1-3/4

diameter) 

in the plate. 

Terminations shall be either closed loop
terminals or open-end spade lugs with
upturned ends. You must use a clamp or
strain relief to hold the cord. 

ELECTRICAL REQUIREMENTS

CAUTION:

For personal safety, 

do not use an extension cord with this
appliance. Remove house fuse or open 
circuit breaker before beginning installation.

This appliance must be supplied with the
proper voltage and frequency, and connected
to an individual properly grounded branch
circuit, protected by a circuit breaker or fuse
having amperage as specified on the rating
plate. The rating plate is located above the
storage drawer on the oven frame.

We recommend you have the electrical wiring
and hookup of your range connected by a
qualified electrician. After installation, have
the electrician show you where your main
range disconnect is located.

Check with your local utilities for electrical
codes which apply in your area. Failure to
wire your oven according to governing codes
could result in a hazardous condition. If there
are no local codes, your range must be wired
and fused to meet the requirements of the
National Electrical Code, ANSI/NFPA No. 70—
Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA  02269

Effective January 1, 1996, the National
Electrical Code requires that new construction
(not existing) utilize a 4-conductor connection
to an electric range.

When installing an electric range in new
construction, follow Steps 3 and 5 for 4-wire
connection.

You must use a 3-wire, single-phase A.C.
208Y/120 Volt or 240/120 Volt, 60 hertz
electrical system.

If the electrical service provided does not
meet the above specifications, have a
licensed electrician install an approved outlet.

Fig. 12A

Fig. 12B

Содержание JSP26

Страница 1: ...his appliance must be properly grounded FOR YOUR SAFETY CAUTION For Personal Safety remove house fuse or open circuit breaker before beginning installation Failure to do so could result in serious inj...

Страница 2: ...und inside the prepack of the oven and save packaging tape 1 ANTI TIP DEVICE INSTALLATION Before placing range in the counter check the factory location of the stability device on the back of the rang...

Страница 3: ...a minimum clearance of 6 must be maintained For listed over the range microwave ovens the microwave ovens can be installed above the cooktop as per manufacturer s installation instructions The range...

Страница 4: ...chrome JXS33 almond JXS34 black or JXS35 bisque or a Main Top Rear Filler Kit Model JXS62BB black JXS63WW white JXS64AA almond or JXS65CC bisque These kits are available through your GE dealer if the...

Страница 5: ...1 is greater than the standard 1 1 8 there will be a small gap between the wall behind the range and the backguard This is normal and should not be visually objectionable 5 SIDE TRIM EXTENSION KIT If...

Страница 6: ...sion cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied with the proper voltage and frequency and connected to an individu...

Страница 7: ...installed before reinstalling the rear range wiring cover Skip to applicable power cord installation 1 Power cord Strain relief Terminal block Bracket CONDUIT AND SQUEEZE CONNECTOR INSTALLATION For c...

Страница 8: ...s securely into the terminal block Re intall the junction block access cover making sure that wires do not become pinched between wire cover and mainback E D C B A 4 3 WIRE POWER CORD INSTALLATION WAR...

Страница 9: ...pinched between wire cover and mainback B A 5 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut a...

Страница 10: ...in cutout until you are sure that the flanges below the sides of the cooktop are above the top of the counter Lift cooktop to see flanges Damage to the cooktop could result if adjusted improperly Inst...

Страница 11: ...he following is a suggested method of making a filler for the toe space when the legs are extended as mentioned before After the range is installed with the longer legs and is in position and level me...

Страница 12: ...12 Notes Printed in the United States...

Отзывы: