GE JN327, JV327, JV337, JV347 Скачать руководство пользователя страница 4

WARNING—TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring 

must be done by qualified persons(s) in
accordance with all applicable codes and
standards, including fire-rated construction.

B. When cutting or drilling into wall or ceiling, 

do not damage electrical wiring and other 
hidden utilities.

C. Ducted fans must always be vented to the

outdoors.

WARNING—To reduce the risk of fire,
use only metal ductwork.

Important—Save for the local electrical
inspector’s use.

JN327

JV327

JV337

JV347

Installation Instructions for
General Electric Hood

Power supply connection box
on underside of hood.

Exhaust Outlet

12

12

5

1

2

5

1

2

12

17

1

2

17

1

2

5

1

2

17

1

2

30

Power supply connection box
on underside of hood.

Exhaust Outlet

30

Exhaust Outlet Knockouts

4

Power supply connection box
on underside of hood.

30

5

1

2

12

17

1

2

Exhaust Outlet

Knockouts

Power supply
connection box on
underside of hood.

30

For ducted installations, 
remove the baffle and re-install
so the short side marked
“VENTED” is visible. The long
side of the baffle should be
inside the hood.

Содержание JN327, JV327, JV337, JV347

Страница 1: ...flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Asso...

Страница 2: ...uld result in damage to the unit and or create an electrical safety hazard READ AND SAVE THESE INSTRUCTIONS Models JN327 JV347 non ducted installations only Your hood is equipped with a replaceable ch...

Страница 3: ...filter Frequency of cleaning depends on hood use and the type of cooking you do HOWEVER THE GREASE FILTER SHOULD BE CLEANED AT LEAST ONCE A MONTH NEVER OPERATE THE HOOD WITHOUT THE FILTER IN PLACE To...

Страница 4: ...e only metal ductwork Important Save for the local electrical inspector s use JN327 JV327 JV337 JV347 Installation Instructions for General Electric Hood Power supply connection box on underside of ho...

Страница 5: ...Model JV327 See Figs 4 9 The hood has been designed to mate with a standard 7 round duct A round damper kit may be ordered Order GE model number JXDA22 A If a rectangular duct is desired a round to r...

Страница 6: ...fined as total feet straight duct plus equivalent feet of elbows transitions wall caps etc Figure 7a shows the approximate equivalent feet of some typical round 6 dia duct elements and rectangular 31...

Страница 7: ...or the mounting screws in the small end of the keyhole 3 Partially drive the 4 mounting screws so that the heads of the screws extend 1 2 below the bottom of the cabinet Raise the hood against the bot...

Страница 8: ...lectrical connections should be inspected carefully before the power is turned on to make certain that none have come loose during shipment 7 Reinstall the connection box cover 8 Install a lamp not su...

Страница 9: ...ith 2 fingers until the side prongs are released Lift the lamp cover and slide toward you in one motion To replace the lamp cover Insert the prong located at the end of the cover into the top opening...

Страница 10: ...be checked and corrected before using the hood again FAN OPERATES BUT Check to be sure the filter is clean If replacing the filter does not correct the problem MOVES AIR SLOWER call for service THAN...

Страница 11: ...ncerning your hood If You Need Service To obtain service see your warranty on the back page of this guide We re proud of our service and want you to be pleased If for some reason you are not happy wit...

Страница 12: ...electrical gas exhausting and other connecting facilities as described in the Installation Instructions provided with the product Replacement of the replaceable filters Replacement of house fuses or...

Отзывы: