GE JN322, JN334, JN335, JN634, JN635, JV322, JV324, JV332, JV334, JV335, JV624, JV634, JV635 Скачать руководство пользователя страница 7

3. POWER SUPPLY

A. CIRCUIT VOLTAGE: This hood must be connected

to a supply circuit of the proper voltage and frequency
as specified on the rating plate. Wire size must
conform to the requirements of the National Electrical
Code or the prevailing local code for hoods of this
rating. The rating plate is located on the rear wall
of the hood.

B. FUSE RATING: 15 

C. Unless otherwise specified by local codes, bring

a 15 amp 2 wire circuit with ground to the area of
the power supply connection box.

D. USE OF OPTIONAL TOP POWER SUPPLY:

The power supply can be attached through the top
knockout if desired, but only the top or back knockout

shall be opened (See Figs. 8, 9 and 10).

Exhaust outlet connects to 

 x 10” rectangular duct; outlet has TOTAL

ADJUSTMENT of 

 from side to side to simplify duct alignment.

I 112” 

Power supply   

 

 

entrance openings

NOTE: Use of REAR opening

I

is recommended

FIGURE  10

Centerline of hood

FIGURE 8

is recommended.

Exhaust outlet connects to 7“ dia. duct.

Centerline of hood

Power supply

entrance openings

in top and rear of hood.
NOTE: Use of REAR
opening is recommended.

FIGURE 9

4. HOOD INSTALLATION

A. MECHANICAL

NOTE: When possible, it is more convenient to mount
and wire the hood before the base cabinet is put in place.

1. Take out 1 screw and remove the power supply

connection box cover located on the underside
of the hood (see Fig. 14). (Models: JV322, JV324,
and 

2. To locate the 4 mounting holes, position the hood

carefully against the bottom of the wall cabinet and
mark the screw positions through the keyhole slots in

the hood. Drill 3/32” pilot holes for the mounting
screws in the small end of the keyhole.

FIGURE

 of

movement for mounting

3. Partially drive the 4 mounting screws so that the

heads of the screws extend 1/2” below the bottom of
the cabinet. Raise the hood against the bottom of the
cabinet, making sure that the heads of the mounting

screws protrude through the hole section of the

keyhole slots as shown in Fig. 11. Before tightening
the mounting screws, attach the power supply cable
to the hood. Then push the hood back against the

wall and tighten the mounting screws.

11

7

Содержание JN322, JN334, JN335, JN634, JN635, JV322, JV324, JV332, JV334, JV335, JV624, JV634, JV635

Страница 1: ...y grounded by a range hood may not withstand the resulting qualified technician in accordance with the excessive heat installation instructions Keep the hood clean and clean grease filter or Have the installer show you the location of the hood circuit breaker or fuse and mark it for replace combination filter as recommended to maintain good venting and to avoid grease fires easy reference Take the...

Страница 2: ...he fire is small andcontained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Your hood is equipped with a metal grease filter When the fan is operated air is drawn through the filter and discharged to the outside SAVE THESE C Models JV332 JV334 JV335 JV634 JV635 INSTRUCTIONS Some models have 1 otate to remove the filter t Greas...

Страница 3: ...e retaining clip to release the edge of the filter The filter will then slip out of the retaining tabs To clean Soak and then agitate in a hot detergent solution Light brushing may be used to remove irnbedded soil Rinse shake and remove moisture before replacing With careful handling the filter will last for yean If replacement becomes necessary order the part from your dealer To replace Slip the ...

Страница 4: ...ctric Hood Models JN322 JN334 JN335 JN634 JN635 JV322 JV324 JV332 JV334 JV335 JV624 JV634 JV635 Important save for the local electrical inspector use Power supply connection box on underside of hood I 7 pe C Y models Exhaust Outlet Knockouts 4 ...

Страница 5: ...BINET WITH FLUSH BOTTOM In some cases it may be necessary to provide clearance for the connection box cover mounting screw which extends slightly through the top of the hood Clearance can be provided if necessary by carefully positioning the hood against the bottom of the cabinet and marking the screw position clearance may then be provided by drilling a 1 4 hole in the cabinet bottom lGURE1 1X di...

Страница 6: ...pared at the time it is constructed by leaving enough space between wall studs to accommodate exhaust MAXIMUM DUCT LENGTH For satisfactory air movement CFM the total duct length should not exceed 65 equivalent feet of 3fi x 10 rectangular duct Equivalent feet are defined as total feet straight duct plus equivalent feet of elbows transitions wall caps etc Figure 7a shows the approximate equivalent ...

Страница 7: ... connects to 7 dia duct Centerline of hood Power supply 7Y4 entrance openings 1 in top and rear of hood NOTE Use of REAR opening is recommended FIGURE 9 4 HOOD INSTALLATION A MECHANICAL NOTE When possible it is more convenient to mount and wire the hood before the base cabinet is put in place 1 Take out 1 screw and remove the power supply connection box cover located on the underside of the hood s...

Страница 8: ...IRING TO THESE COPPER LEADS CAN RESULT IN A SERIOUS PROBLEM USE ONLY CONNECTORS DESIGNED FOR JOINING COPPER TO ALUMINUM AND FOLLOW THE MANUFACTURER S RECOMMENDED PROCEDURE CLOSELY 5 A ground lug is provided for proper grounding of he hood frm e It is recommended that the hood frame be grounded in accordance with National Electrical Code and local codes see Figs 13 and 14 6 All electrical connectio...

Страница 9: ...mp cover Lift the lamp cover and slide towards you in one The lamp cover need not be motion removed for lamp removal To replace the lamp cover or installation Insert the prong located at the end of the cover into the to oDenin CAUTION Let the lamp cool completely before 1 Gently push the cover up and press the sides to fit removing A warm or hot bulb may break if touched with a moist cloth or hand...

Страница 10: ...and corrected before using the hood again FAN OPERATES BUT Check to be sure the filter is clean If replacing the filter does not correct the problem MOVES AIR SLOWER call for service THAN NORMAL FAN KEEPS GOING The motor is probably overheating and turning itself off This can be harmful to the OFF AND ON motor Check to be sure the filter is clean If off and on cycling continues call for service If...

Страница 11: ...r warranty on the back page of this book We re proud of our service and want you to be pleased If for some reason you are not happy with the service you receive here are 3 steps to follow for further help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including yo...

Страница 12: ...setting of circuit breakers about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Center 800 626 2000 consumer information service Failure of the product if it is used for other than its intended purpose or used commercially Damage to product caused by accident fire floods or acts of God Improper installation WARRANTO...