Dimensions and Installation Information (in inches)
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
320442
Specification Revised 10/07
JKP30BM/CM/WM
GE
®
27" Built-In Single Wall Oven
Listed by
Underwriters
Laboratories
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Undercounter Installation Dimensions
Sealed Burner Gas Cooktop
Installation Dimensions
Standard Burner Gas Cooktop
Installation Dimensions
25
Gas or electric cooktops may be installed over this
oven. See cooktop installation instructions for cutout size.
See label on top of oven for approved cooktop models.
Gas or electric connections
for gas cooktop must be
located in an adjacent
accessible location to the right
5
240V / 208V
Junction Box
Location
36"
Typical
Countertop
Height
24
Allow 1"
unit overlap
all edges
25" MIN.
25 1/4" MAX.
27 5/8" MIN.
28 1/8" MAX.
3/4" Support
Platform Required
Must Support 150 Lbs.
22" MIN.
Above
Support
Platform
Note:
Oven is rated for use only under 30" standard or sealed burner gas
and selected 30" CleanDesign and Calrod
®
electric cooktops.
Installation Information:
Before installing, consult installation instructions
packed with product for current dimensional data.
90
°
Street el
45
°
Elbow
Cabinet sides
2" Diameter hole (20-7/8"
from front of countertop
to hole center)
Sealed Burner Gas Cooktop Installation
(Pub. 1-G003 pg. 107) May 11, 1993
5" To center of 2" diameter
hole from countertop
90° Street el
45° Elbow
To center of 2" diameter
hole from countertop
Cabinet sides
3-7/16"
2" MIN. diameter hole
(23-1/4" from front
surface of countertop)
Standard Burner Gas Cooktop Installation
(Pub. 1-G003 pg. 107) May 11, 1993
Note:
Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.
Electric wall ovens are not approved for installation with a plug
and receptacle. They must be hard wired in accordance with
installation instructions.