background image

CONVERT THE PRESSURE
REGULATOR

Locate the pressure regulator under the front of
the cooktop.

Remove the nut from the pressure regulator with
an adjustable wrench.

Remove the plastic pin from the inside of the 
nut, turn the pin 180° and snap the pin back 
into the nut.

Re-install the nut onto the regulator.

Apply the LP Conversion label next to the 
Rating Plate.

E

D

C

B

A

1

2

LP Conversion Instructions

Nut

Natural gas

LP gas

Nut

Natural gas

LP gas

GAS SUPPLY

• 

With the installation of this conversion kit, the cooktop
should operate on LP gas at 10

of water column

pressure.

• 

The pressure regulator must be connected in series 
with the manifold of the cooktop and must remain in
series with the supply line. For proper operation, the
maximum inlet pressure to the regulator must be no
more than 14

water column pressure for LP gas.

• 

When checking the regulator, the inlet pressure must 
be at least 1

greater than the regulator output setting. 

If the regulator is set for 10

of water column pressure,

the inlet pressure must be at least 11.

IMPORTANT –

Disconnect the cooktop

and the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.

TURN OFF GAS AND
ELECTRIC SUPPLY

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY 
AT THE SHUT-OFF VALVE. DISCONNECT THE
ELECTRICAL SUPPLY FROM THE COOKTOP.

Shut-off valve

Electrical supply