background image

– 8 –

Adjusting Low Flame Setting

WARNING: The following adjustments must be
made before turning on the burner. Failure to do so
could result in serious injury. Be sure pressure
regulator has been converted.

The top burner valves have low flame/simmer
adjustment screws in the center of the control
shafts. A flashlight may be needed to locate the
screw. A small thin-blade screwdriver (approxi-
mately 3/32-in. blade width) is needed to access
the screw.

1.  Light 2 other burners and set the knob to a

Medium to Hi setting.

2.  Light the burner to be adjusted and turn the

knob to LOW.

                     

GEA00757

3.  Remove the knob and insert a screwdriver into

the valve shaft.

4.  Turn the adjustment screw until the flame

reaches the desired size.

5.  Perform a flame stability test.

Flame Adjustments

The burners do not have air shutters adjustments
and use nonadjustable orifices. If the flame lifts off
of the burner, or if you experience “Yellow Tip”
flames and/or soot in the flames, be sure to check
the following:

1.  Gas pressure: 4-in. W.C.P. (natural) and 10-in.

W.C.P. (LP).

2.  Inspect orifice to be sure it is drilled in the

center and free of debris or burrs.

3.  Be sure the correct size orifice is in the proper

location.

4.  Make sure the cooktop was properly converted

if on LP.

5.  If the cause of sooting can not be found in the

above checks, replace the orifice with one
having a smaller diameter opening.

Testing Flame Stability

1.  Turn the knob from HI to LOW quickly. If the

LOW flame goes out, increase the flame size
and test again.

2.  With the burner on the LOW setting, open and

close the cabinet door under the cooktop. If the
flame is extinguished by the air currents cre-
ated by the door movement, increase the flame
height and test again.

Flame Recheck

After the adjustment is made, turn all burners off.
Ignite each burner individually. Observe the flame
at the HI position. Rotate the valve to the LOW
position and be sure the flame size decreases as
the valve is rotated counterclockwise.

Note: Once the conversion is complete and
checked OK, fill out the LP sticker and include
your name, organization, and date conversion was
made. Apply the sticker near the cooktop gas inlet
opening to alert others in the future that this
appliance has been converted to LP. If converting
back to natural gas from LP, please remove the
sticker so others know the appliance is set to use
natural gas.

Содержание JGP328

Страница 1: ...C PUB 31 9069 12 00 MODEL SERIES TECHNICAL SERVICE GUIDE GE Consumer Home Services Training Cooktop Revitalization Gas Model 36 INCH 30 INCH JGP628 JGP328 JGP962 JGP932 JGP963 JGP933 ...

Страница 2: ... do not use any phone in the building Immediately call the gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department WARNING To avoid personal injury disconnect power before servicing this product If electrical power is required for diagnosis or test purposes disconnect the power immediately after performing the necess...

Страница 3: ...nstallation 3 Conversion to LP Propane Gas 6 Specifications and Nomenclature5 9 Warranty Information 10 Cooktop Features and Controls 11 Mechanical Disassembly 15 Troubleshooting 21 Component and Connector Locator Views 22 Schematics 24 Parts List 26 Title ...

Страница 4: ...sons you ll find these gas cooktops superior blend of form and function will be a delight for years to come These cooktops contain several new features such as glass or deepdish cooktop surfaces and sealed burners Most all of the service proce dures for these cooktops can be performed without removing the cooktop from the countertop The information on the following pages will help you service thes...

Страница 5: ... of the Cooktop GEA00737 BURNER GRATE BURNER CAP BURNER HEAD SPARK IGNITER BURNER BASE BURNER BOX BOTTOM GEA00738 3 3 4 MIN clearance from cutout to side wall on the left of the unit 30 MIN clearance from countertop to unprotected overhead surface 6 MIN clearance from cutout to side wall on the right of the unit 13 MAX Depth of unprotected overhead cabinets 18 MIN height from countertop to nearest...

Страница 6: ...NER CAP BURNER HEAD SPARK IGNITER BURNER BOX BOTTOM BURNER BASE GEA00742 13 MAX Depth of unprotected overhead cabinets 30 MIN clearance from countertop to unprotected unprotected overhead surface 2 MIN clearance from cutout to side wall on the right of the unit 18 MIN height from countertop to nearest cabinet on either side of unit 2 MIN clearance from cutout to side wall on the left of the unit C...

Страница 7: ... with a gas shutoff valve When installed correctly a shutoff valve will be in the main gas supply line down stream of the appliance pressure regulator Disconnect the electrical supply before servicing Wall coverings countertops and cabinets should be able to withstand 200 F heat generated by the cooktop Avoid placing cabinets above the cooktop If cabinets are placed above the cooktop use cabinets ...

Страница 8: ...ter of the cap 4 Turn plastic spring retainer upside down so that LP is showing at the bottom see illustration above and reinstall spring retainer in the spring retainer cap 5 Assemble the cap on the pressure regulator Install the LP Orifices 1 Remove the top grates burner caps burner head and spark igniter from the burner base GEA00747 ORIFICE SPUD LOCATED THRU THIS OPENING REMOVE THIS ASSEMBLY 2...

Страница 9: ...OPANE GAS 10 W C P BTU RATE ORIF SIZE RR 6 000 1 18 Nmm LR 11 000 1 61 Nmm LF 9 100 1 50 Nmm RF 15 000 1 93 Nmm BURNER OUTPUT RATING BTU HR ORIF SIZE BTU RATE BURNER Natural Gas 4 W C P GEA00751 III II I X GEA00752 RR 6 000 1 18 Nmm LR 9 100 1 50 Nmm LF 9 100 1 50 Nmm RF 9 100 1 50 Nmm BURNER RR 6 000 79 Lmm LR 8 100 84 Lmm LF 8 100 84 Lmm RF 8 100 84 Lmm BURNER OUTPUT RATING BTU HR LP PROPANE GAS...

Страница 10: ...rilled in the center and free of debris or burrs 3 Be sure the correct size orifice is in the proper location 4 Make sure the cooktop was properly converted if on LP 5 If the cause of sooting can not be found in the above checks replace the orifice with one having a smaller diameter opening Testing Flame Stability 1 Turn the knob from HI to LOW quickly If the LOW flame goes out increase the flame ...

Страница 11: ...years Example T 1974 T 1986 T 1998 J G P 9 6 3 B E C Product J GE Cooking Product Features G Gas Configuration P Cooktop Feature Pack Designates features the higher the number the more features Grate Type C Continuous Ignition System Gas Models E Electronic Pilotless Ignition Glass Color B Black Glass The serial plate of your cooktop is located on the bottom of the burner box In addition to the mo...

Страница 12: ......

Страница 13: ...trols 5 Glass Cooktop Surface 6 Cast Iron Burner Grates Some models The new gas cooktop revitalization encompasses over 20 models of gas cooktops It includes 30 in 4 burner and 36 in 5 burner models in both deepdish metal and glass cooktop configurations All gas cooktop revitalization models have spill proof burners and electric ignition systems 36 in Glasstop Cooktop 36 in Deepdish Cooktop 30 in ...

Страница 14: ...ed Enameled Continuous Continuous Continuous Continuous Continuous Continuous Chrom e Stainless Stainless White White White Stainless White Stainless Bisque Bisque White Bisque White Bisque White Almond Almond Bisque Bisque Black Black Black Black Black Black Black Black White Black Controls Upfront Upfront Upfront Upfront Appearance SS SS WW WW WW SS WW SS AA AA WW WW CC WW CC WW BB BB CC CC BB B...

Страница 15: ......

Страница 16: ......

Страница 17: ...Burner and Top Removal 16 Burner Bracket Removal 17 Spark Module Removal 17 Igniter Switch Removal 18 Valve Removal 18 36 in Models 18 30 in Models 18 Manifold Removal 19 36 in Models 19 30 in Models 19 Brace Removal 20 Mechanical Disassembly ...

Страница 18: ...and the burner box nonglass models only This gasket must stay in place to ensure proper air flow to the burners see Igniter Re moval illustration Note The cooktop itself is not equipped with a gas shutoff valve If installed correctly a shutoff valve will be in the main gas supply line downstream of the appliance pressure regulator Igniter Removal 1 Remove the burner grate burner cap and burner hea...

Страница 19: ...o the burner bracket 6 Remove 2 screws 1 4 in and the igniter wire from the burner bracket Note When installing be sure the igniter wire is placed through the hole with the retainer clip Spark Module Removal 1 Remove insulation material if applicable 2 Note positions and unplug the wires to the spark module GEA00775 30 in Model 30 in Model 30 in Model Spark Module Spark Module 1 4 in Screw 1 4 in ...

Страница 20: ...oval GEA00778 Igniter Switch Switch Igniter Switch 2 Lift the igniter switches off the valve stems Note the color and positions of the switches GEA00779 Straight Straight Manifold Manifold Straight Manifold 5 8 in Nut 5 8 in Nut 5 8 in Nut 1 2 in Nut 1 2 in Nut 1 2 in Nut 3 Remove the 1 2 in nut on the gas line to the valve and remove the gas line 4 Remove the 5 8 in nut on the gas line to the hor...

Страница 21: ...lve stems Note the color and positions of the switches GEA00841 Straight Manifold Straight Manifold 5 8 in Nut 5 8 in Nut 1 2 in Nut 1 2 in Nut 1 4 in Nut 1 4 in Nut 3 Remove the 1 2 in nuts 5 on the gas lines to the valves and remove the gas lines 4 Remove the 5 8 in nut on the gas line to the horseshoe shaped manifold or the 9 16 in nut on the gas line to the straight manifold and remove the gas...

Страница 22: ...1 4 in Screws 1 4 in Screws 1 4 in Screws 1 4 in Screws Screws 1 4 in Screws 5 Remove the 1 4 in screws 2 from the right side exterior of the burner box 6 Remove the 1 4 in screws 4 from the mani fold and remove the manifold from the burner box 7 Remove the 1 4 in screws 4 from the mani fold and remove the valves Brace Removal 1 Remove the burners and top see Burner and Top Removal 2 Remove the bu...

Страница 23: ... burner flames are normal If the burner flames look like A see Flame Adjustments Normal burner flames should look like B or C depending on the type of gas you use With LP gas some yellow tipping on outer cones is normal A Yellowflames B Yellowtips C Softblueflames Call for service on outer cones Normal for natural Normal for LPgas gas Make sure electrical plug is plugged into a live properly groun...

Страница 24: ...lve Igniter Switch Igniter Switch Burner Support Burner Support Brace Brace Igniter Retainer Igniter Retainer Igniter Wire Igniter Wire GEA00787 Spark Module Spark Module Manifold Manifold Igniter Switch Igniter Switch Valve Valve Graphite Gasket Graphite Gasket Brace Brace Burner Supoort Burner Support Igniter Retainer Igniter Retainer Igniter Wire Igniter Wire Burner Bracket Burner Bracket ...

Страница 25: ... 23 Notes ...

Страница 26: ...nection when servicing the controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing L BLACK BURNER IGNITERS CLEAR TOP BURNER IGNITION SWITCHES WHITE N N L WHITE IGNITION UNIT GEA00788 CLEAR CLEAR CLEAR CLEAR ...

Страница 27: ... 25 Notes ...

Страница 28: ... 26 Parts List Table of Contents Model JGP962 27 Model JGP933 32 ...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Отзывы: