All GE ranges are equipped 

with an Anti-Tip device. 

The installation of this 

device is an important, 

required step in the  

installation of the range.

Dimensions and Installation Information (in inches) 

Specification Created 6/13

330445

Electrical Rating: 120V, 60Hz, 5A
Installation Information: Before installing,  
consult installation instructions packed with 
product for current dimensional data.

JGBS10GEF 

GE

® 

30" Free-Standing Gas Range

 

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

1"

30"

30"

13"

1"

36"

0"

Front edge of

the range side

panel forward

from cabinet

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 240V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

46 1/4"

28 3/4"

w/ handle

26 1/4"

w/o handle

30"

10 1/4"

36"

to

36 1/2"

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

1"

30"

30"

13"

1"

36"

0"

Front edge of

the range side

panel forward

from cabinet

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 240V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

46 1/4"

28 3/4"

w/ handle

26 1/4"

w/o handle

30"

10 1/4"

36"

to

36 1/2"

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

1"

30"

30"

13"

1"

36"

0"

Front edge of

the range side

panel forward

from cabinet

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 240V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

46 1/4"

28 3/4"

w/ handle

26 1/4"

w/o handle

30"

10 1/4"

36"

to

36 1/2"

* ADA qualified based 

on Uniform Federal 

Accessibility Standards

*

Отзывы: