SURFACE BURNERS
MODELS EQUIPPED WITH SEALED BURNERS
(See
Step
4 if
range is equipped with standard
1.
Remove the grates, burner caps and burner
heads.
2. Using the
remove the burner bases
by unscrewing the 3 small screws in each base.
the
burner straight out.
DO
disconnect the wires from the burner
bases unless the
needs to be raised.
3. Remove the brass
spud under each
burner base by unscrewing spud from fitting
with a
or small adjustable wrench
(depending on the size of your spuds).
Apply a
3/4” wrench to the hex on the gas inlet tube
as a back-up when removing spud to prevent
the aluminum
twisting.
4.
Install orifice spuds according to one of
the following diagrams (see
❑
or
❑
) for
gas or natural gas, depending on
you are
converting to.
❑
Spuds for Converting to
Gas:
orifice spuds are in a small
with this Use and Care Guide.
orifice spuds
have a 2-digit number and the letter “L” on one
side. Each orifice spud will also have 1 or 2
grooves on one side, denoting the location on the
range where it is to be installed as shown below.
❑
Converting to
Gas:
Natural gas
spuds have a 3-digit number
on one side. Each
spud will also have 1, 2
or 3 grooves on one side, with the letter “N”
underneath denoting the location on the range
where it is to be installed as shown below.
Front of Range
(continued next page)
41