Installation Instructions

ELECTRICAL CONNECTIONS 

(CONT.)

4-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral wire of 

the supply circuit must be connected to the
neutral terminal located in the lower center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block. The 4th
grounding lead must be connected to the
frame of the range with the ground plate 
and the ground screw.

Remove the 3 lower terminal screws from
the terminal block. Remove the ground
screw and ground plate and retain them.

Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.

Insert the one ground screw into the power
cord ground wire terminal ring, through the
ground plate and into the frame of the range.

Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securely
into the terminal block.

Skip to Step 8 and proceed with the installation.

E

D

C

B

A

5

3-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral or ground

wire of the power cord must be connected
to the neutral terminal located in the
center of the terminal block. The power
leads must be connected to the lower left
and the lower right terminals of the
terminal block.

Remove the 3 lower terminal screws
from the terminal block. Insert the 3
terminal screws through each power cord
terminal ring and into the lower terminals
of the terminal block. Be certain that the
center wire (white/neutral) is connected
to the center lower position of the
terminal block. Tighten screws securely
into the terminal block.

DO NOT remove the ground strap
connection.

Skip to Step 8 and proceed with the
installation.

B

A

4

Ground
strap

Terminal
block 
(appearance
may vary)

Neutral
terminal

Power cord

Before

After

Terminal
block

Terminal
block

Neutral
terminal

Neutral terminal

Ground strap

Ground
plate
(grounding
to range)

Ground
screw

Ground strap 

Ground
plate

or

Содержание JBP99

Страница 1: ...RNING This appliance must be properly grounded FOR YOUR SAFETY WARNING Before beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power fro...

Страница 2: ...eper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F g...

Страница 3: ...ng MINIMUM DIMENSIONS BETWEEN COOKTOP WALLS AND ABOVE THE COOKTOP Make sure the wall covering countertop and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 3...

Страница 4: ...plied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse having amperage as specified on the rating plate The...

Страница 5: ...train relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover...

Страница 6: ...ral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block Skip to Step 8 and proceed with the installation E D C B A 5 3 WIRE POWER CORD INSTA...

Страница 7: ...ocal codes Skip to Step 8 and proceed with the installation B A 6 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate an...

Страница 8: ...nstall supplied with bracket Unless properly installed the range could be tipped by stepping or sitting on the door Injury may result from spilled hot liquids or from the range itself 9 Typical instal...

Страница 9: ...door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted...

Страница 10: ...10 Notes...

Страница 11: ...11 Notes...

Страница 12: ...12 Printed in the United States...

Отзывы: