23
Safety Instructions
Operating Instructions
Care and Cleaning
Troubleshooting T
ips
Customer Service
Oven Light Bulb
(on some models)
NOTE:
The glass cover (on some
models) should be removed only when
cold. Wearing latex gloves may offer a
better grip.
Before replacing the bulb, disconnect
electrical power to the range at the main
fuse or circuit breaker panel. Let the bulb
cool completely before removing it. For
your safety, do not touch a hot bulb with a
damp cloth. If you do, the bulb will break.
To remove:
Turn the glass cover counterclockwise
1/4 turn until the tabs of the glass cover
clears the grooves of the socket. Remove
the bulb.
To replace:
Put in a new 40-watt appliance bulb. Place
the tabs of the glass cover into the groove
of the socket. Turn the glass cover
clockwise 1/4 turn.
NOTE:
■
A 40-watt appliance bulb is smaller than a
standard 40-watt household bulb.
■
Reconnect electrical power to the range.
■
For improved lighting inside the oven, clean
the glass cover frequently using a wet cloth.
This should be done when the oven is
completely cool.
Bulb
Socket
Tab
Maximum
length
3
1
⁄
2
”
Glass cover
Anti-Tip Device
(for kit number 342473)
WARNING:
All ranges can
tip and injury could result. Install the
Anti-Tip device packed with the range.
Follow the installation instructions
below.
Tools needed:
■
Phillips head screwdriver
■
1
3
⁄
8
″
open end or adjustable wrench
The bracket attaches to floor or wall to
hold either the right or left rear leg
leveler. If fastening to the floor, be sure
that the screws do not penetrate electrical
wiring or plumbing. If this cannot be
determined, use shorter screws that will
not penetrate through flooring.
The bracket is packed inside the oven. Remove
and follow the instructions below.
Decide whether the bracket will be
installed on the right or left side of
the range location.
If the bracket side of the range is
adjacent to a cabinet, place the
bracket against back wall and
cabinet.
If there is no adjacent cabinet, determine where
the location of the range side (painted outside
panel) will be. Place the bracket with its outside
edge at this location and against the back wall.
Determine whether you will anchor
the bracket to the floor or wall.
Fasten the bracket securely with the
screws provided. The screws are self-
drilling in wood, plywood, particle
and chip board, and most metal
framing.
If attaching to masonry you can buy suitable
screws and anchors at hardware stores. Use a
masonry drill to drill the required holes.
Using the wrench, back out the four
leg levelers at least two turns. See the
installation instructions for more
leveling information before
positioning range.
Slide the range into place. Be sure
the rear leg leveler fully engages the
slot in the bracket.
If the range cannot be moved back far enough for
the rear leg leveler to enter the bracket, move the
bracket forward as required and attach to the
floor in the new location.
Wall behind
range
Outside edge of
bracket to be
flush with left
or right side of
range
Adjacent cabinet
or final location of
range side panel
Make sure leg leveler engages slot.
Attachment to wall.
Wall plate
Bracket
Screw must enter
wood or metal.