Table 4.  Boolean Signals

Request Bits
Innovation Series
bit #

Innovation
Series
Mnemonic

AcDc2000

Feedback Bits
AcDc2000
bit #

Innovation
Series
Mnemonic

Innovation
Series

0

Heartbeat ref, lan

LAN_HTBT_REF

AUXCMD00

0

AUXFB00

LAN_HTBT_FBK Heartbeat fbk, lan

1

Fault reset req, lan

LAN_FLT_RST

SOFTRES

1

NOFAULT

NO_FLT

No faults active

2

Trip request, lan

LAN_TRP_REQ

CFGCMD32 (V.1422)

2

TRIPFLT

TRIP_FLT

Trip fault active

3

Alarm request, lan

LAN_ALM_REQ

CFGCMD33 (V.1423)

3

AUXFBW32.0

LOC_FLT

Local Fault string

4

Undefined

4

AUXFBW32.1

SYS_FLT

System fault string

5

Undefined

5

AUXFBW32.2

RUN_RDY

Ready to Run

6

Undefined

6

MPWRENAB

BRG_PWR_ENB Bridge is on

7

Undefined

7

RUNNING

RUNNING

Running

8

Run request, lan

LAN_RUN_REQ

RUNRQ  (V.650)

8

RUNACT

RUN_ACT

Run Active

9

Jog request, lan

LAN_JOG_REQ

JOGRQ  (V.651)

9

JOGACT

JOG_ACT

Jog Active

10

X stop request, lan

LAN_XSTP_REQ

CFGCMD34 (V.1424)

10

AUXFBW32.3

X_STP_CMD

X stop active

11

Full flux req, lan

LAN_FFLX_REQ

CFGCMD35 (V.1425)

11

AUXFBW32.4

FLX_ENB_STAT Flux enable status

12

Rev mode req, lan

LAN_REV_REQ

REVCMD  (V.675)

12

AUXFBW32.5

REVERSE

Reverse mode
active

13

Torque mode req, lan LAN_TREF_ENB

CURFOLRQ  (V.684)

13

AUXFBW32.6

TRQ_MODE_ACT Torque mode

active

14

Droop disab req, lan

LAN_DRP_INH

BIASDINH  (V.724)

14

AUXFBW32.7

SPD_MODE_ACT Speed mode active

15

Trq lim 2 sel, lan

LAN_TLIM_SEL

RCLILIM  (V.695)

15

AUXFBW32.8

TRQ_LIM_ACT

In cur or trq limit

16

Ramp rate 2 sel, lan

LAN_RMP_SEL

ALTRAJSU  (V.643)

16

AUXFBW32.9

LOCAL_MODE

Local mode active

17

Ramp hold req, lan

LAN_RMP_HOLD HOLDSPD  (V.699)

17

AUXFBW32.10

MA_ENB_STAT

MA cont enable stat

18

Auto mode req, lan

LAN_AUTO_REQ AUTOCMD  (V.683)

18

Undefined

19

Undefined

19

ZEROSPD

ZERO_SPD

Zero speed active

20

Undefined

20

Undefined

21

Undefined

21

Undefined

22

Undefined

22

Undefined

23

Undefined

23

Undefined

24

GP lan req bit 1

LAN_B01_REQ

AUXCMD01  (V.661)

24

(EE.781)  AUXFB01 LAN_B01_ADR

LAN_B01_ADR

25

GP lan req bit 2

LAN_B02_REQ

AUXCMD02  (V.662)

25

(EE.782)  AUXFB02 LAN_B02_ADR

LAN_B02_ADR

26

GP lan req bit 3

LAN_B03_REQ

AUXCMD03  (V.663)

26

(EE.783)  AUXFB03 LAN_B03_ADR

LAN_B03_ADR

27

GP lan req bit 4

LAN_B04_REQ

AUXCMD04  (V.664)

27

(EE.784)  AUXFB04 LAN_B04_ADR

LAN_B04_ADR

28

GP lan req bit 5

LAN_B05_REQ

AUXCMD05  (V.665)

28

(EE.785)  AUXFB05 LAN_B05_ADR

LAN_B05_ADR

29

GP lan req bit 6

LAN_B06_REQ

AUXCMD06  (V.666)

29

(EE.786)  AUXFB06 LAN_B06_ADR

LAN_B06_ADR

30

GP lan req bit 7

LAN_B07_REQ

AUXCMD07  (V.667)

30

(EE.787)  AUXFB07 LAN_B07_ADR

LAN_B07_ADR

31

GP lan req bit 8

LAN_B08_REQ

AUXCMD08  (V.738)

31

(EE.788)  AUXFB08 LAN_B08_ADR

LAN_B08_ADR

Notes:

For CFGCMDx reference bits to be active, drive EE.762.8 (LDRVJP.8) must be set.
For AUXFBW32.x feedback bits to be active, drive EE.5626 (AUXFBJP) must be set to 3 (bits .1 & .0 must be set).

Содержание IS200ADIIH A Series

Страница 1: ... operation and or maintenance of the equipment described This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Industrial Systems Indicates a procedure or condition that if not strictly observed could result in damage to or destruction of equipment Note Indicates an essential or important procedure or sta...

Страница 2: ...is derived from the Innovation Series drive system applications signal map Many references and feedbacks are generic and AcDc2000 drive blockware must be created to imitate the Innovation Series drive functionality The ADII board provides an integer variable map between the drive and controller The integers must be scaled to the AcDc2000 units given in the signal map definition Configuration of th...

Страница 3: ... The delay time at the end of a frame is shown in Table 1 This time is valid as long as the number of pages per the frame rate is not exceeded Table 1 Frame End Delay Time Frame Rate ms Number of AcDc2000 drives End of Frame Delay Time µ µ µ µs 1 4 200 2 8 400 4 16 800 8 32 1600 AcDc2000 drives use a double page refer to the following timing diagram pg time delay Frame à Frame à End Of Serial Data...

Страница 4: ...econds Set by the master Types of devices on the bus The contribution of each device to the bus sweep rate varies with the quantity of I O data being exchanged with the controller Each AcDc2000 drive contributes about 0 20 ms 200 µs This data is used in calculating what the frame time should be Quantity of devices on the bus As the number of devices on the bus grows so does the bus sweep rate This...

Страница 5: ...DE Fault Number 3 Spd Ref Aux RPM LAN_AUX_RPM SPDSETP V 205 3 LCPSFB V 558 LAN_SPD_FBK Speed Feedback 4 Torque Ref LAN_TRQ_REF LOADADJ V 225 4 EE 5627 LFBVAR7 V 593 LAN_TRQ_FBK Motor Torque 5 Spd Ref Aux Appl LAN_AUX_SPD GS1 V 218 219 DW 5 LCPCFB V 559 LAN_I_MAG Motor Current 6 Ramp Time Ref LAN_RAMP_TM GS3DWA V 1438 6 Undefined 7 GP LAN Ref 1 LAN_R01_REF LANV0SP V 206 7 EE 769 LFBVAR1 V 566 LAN_R...

Страница 6: ...req lan LAN_DRP_INH BIASDINH V 724 14 AUXFBW32 7 SPD_MODE_ACT Speed mode active 15 Trq lim 2 sel lan LAN_TLIM_SEL RCLILIM V 695 15 AUXFBW32 8 TRQ_LIM_ACT In cur or trq limit 16 Ramp rate 2 sel lan LAN_RMP_SEL ALTRAJSU V 643 16 AUXFBW32 9 LOCAL_MODE Local mode active 17 Ramp hold req lan LAN_RMP_HOLD HOLDSPD V 699 17 AUXFBW32 10 MA_ENB_STAT MA cont enable stat 18 Auto mode req lan LAN_AUTO_REQ AUTO...

Страница 7: ...DIIJP1 ADIIJP1 0 Enables the ADII interface When ADII is enabled all other LAN interfaces must be disabled ADIIJP1 14 Disables the ISBus controller ASIC watchdog This is a special diagnostic bit that is normally not set Setting this bit disables the ISBus controller watchdog detection ADIIJP1 15 Enables Loop Back Mode This is a special diagnostic mode that loops the references received back into t...

Страница 8: ...rate a heartbeat to the drive by inverting the heartbeat from the drive and sending that value back to the drive The first bit in the drive s feedback map is used as a heartbeat from the drive to the master controller The drive LCP always writes the heartbeat feedback to the same state as the heartbeat reference Thus the master controller can monitor the status of the communication with the drive ...

Страница 9: ...J45 P2 P3 Replace ADII board 448 FLT_LADIIRTM ADII board run time fault The ISBus controller has a fault or LCP has detected a problem with the ADII board or ISBus controller interface Check replace LNPL and 2PL connections and cables Check the ISBus connections RJ45 P2 P3 Replace ADII board 449 FLT_LADIISEL Another drive LAN is enabled besides ISBus Modify the drive s parameters EEROM to disable ...

Страница 10: ...U2 U5 2PL TP1 TP3 TP2 DS5 DS6 E2 P3 P2 TX OUT RX IN RX TX CHASSIS XMIT DATA IN RELAYS ENABLED P24 P5 DCOM TP6 TP7 TP4 TP5 0BACTIVE1 0ONLN1 DBG1A DBG1B DS1 DS2 DS3 DS4 BUS ACTIVE 1 BUS ONLINE 1 DEBUG G1A DEBUG G1B IS200ADIIH1A ISBus Cable Strain Reliefs Figure 2 ADII Board Layout Diagram ...

Страница 11: ...if modulation on the LAN is detected If this LED is not on then the ISBus Controller is not online See Table 8 for a description of flashing indications DS3 Debug1A Manufacturing use only DS4 Debug1B Manufacturing use only DS5 Bypass Relays Enabled On if these relays are being driven meaning the drive s P5 is OK If this LED is not on then P5 5 V is below 4 6 V or P24 24 V is too low to drive these...

Страница 12: ...nectors There are four plug connectors and two stab on connectors on the ADII board Refer to the following tables for complete descriptions of these connectors Table Description 10 Stab on Connectors 11 2PL Power Connector 12 LNPL Connector to LDCC Board 13 P3 ISBus Connector 14 P2 ISBus Connector Table 10 Stab on Connector Descriptions Connector Nomenclature Description E1 COM1 Common to LDCC boa...

Страница 13: ...al common ground 17 LNALE NC 18 DCOM Digital common ground 19 LNRD ADII board read control signal 20 LNWR ADII board write control signal 21 DCOM Digital common ground 22 34 LNA0 LNA12 ADII board address signals A0 A12 35 P5 5 V dc 36 LNACS Not connected 37 LNCS1 ADII board DPRAM select 38 LNCS2 ADII board ISBus controller select 39 40 DCOM Digital common ground Table 13 P3 Connector RJ45 ISBus RX...

Страница 14: ...the order accurately and as soon as possible Board Identification A printed wiring board is identified by an alphanumeric part catalog number located near its edge Figure 3 explains the structure of the part number The board s functional acronym shown in Figure 3 is normally based on the board description or name For example the ADII board is described as the Auxiliary Drive to ISBus Interface boa...

Страница 15: ...o include the following when ordering any warranty or renewal parts Complete part number and description Drive serial number Drive Material List ML number Note All digits are important when ordering or replacing any board The factory may substitute later versions of replacement boards based on availability and design enhancements However GE Industrial Systems ensures backward compatibility of repl...

Страница 16: ...Board New Installation Part Numbers Part Description Part Number ADII board Auxiliary drive to ISBus interface board IS200ADIIH_A_ _ 2PL Power cable from the power supply board to the LDCC board and ADII board See Table 16 LNPL 40 pin ribbon cable to the LDCC board 336A3493AA G01 DCOM wire Common wire from the LDCC board to the ADII board runs parallel to the LNPL cable 336A3438AT G15 CHASSIS wire...

Страница 17: ... c Place the board in position on the four tabs on left side of the back of this board carrier and press it firmly into position on these tabs 4 Install the LNPL ribbon cable into the LNPL connector on the ADII board and the LNPL connector on the LDCC board 5 Install the COM1 wire onto the E1 COM1 stab on terminal on the ADII board and the E1 COM1 terminal on the LDCC board 6 Install the CHASSIS w...

Страница 18: ... the board before touching it or any connected circuits To prevent equipment damage do not remove insert or adjust board connections while power is applied to the equipment Ø Ø Ø Ø To remove the ADII Board from the drive 1 Make sure that the drive in which the board is to be removed has been deenergized Refer to the appropriate User s Guide for complete de energizing procedures and follow all loca...

Страница 19: ...s Use a wire tie down strap connected to the bottom of the board carrier to keep it away from the power supply board Care must be taken to keep the ISBus cables away from any high voltage wires and any electrically noisy wires Keep the cables tight to the ADII board carrier and use the tie down strap holders to hold the cables close to the ADII board and away from the power supply board 3 Reinstal...

Страница 20: ...ISBus Interface Board IS200ADII GEI 100305 20 Notes g GE Industrial Systems General Electric Company 1501 Roanoke Blvd Salem VA 24153 6492 USA Issue date 2000 04 05 1999 by General Electric Company USA All rights reserved ...

Отзывы: