background image

4

Installation

This chapter provides the following procedures for installing the QuickPanel

+

Operator

Interface:

Installing the Protective Sheet

Choosing a Mounting Location

Panel Mounting

Mounting on a VESA Arm

Installing and Replacing the Battery

Connectors

4.1

Installing the Protective Sheet

To install the protective sheet

1.

Remove the protective film on the screen of the QuickPanel

+

.

2.

Wipe the display of any dust or fingerprints.

3.

Peel a corner of the clear side of the protective sheet.

4.

Begin applying the corner to the display.

5.

Slowly apply the rest of the protective sheet, smoothing out as you go.

6.

Peel the green curing film from the protective sheet.

Installation

GFK-2847F User Manual 27

For public disclosure

Содержание IC755CxW07CD SERIES

Страница 1: ...GE Intelligent Platforms GFK 2847F QuickPanel Operator Interface IC755CxW07CDx 7 Display IC755CxS10CDx 10 Display IC755CxS12CDx 12 Display IC755CxS15CDx 15 Display User Manual For public disclosure...

Страница 2: ...pending patent applications covering subject matter in this document The furnishing of this document does not provide any license whatsoever to any of these patents GE provides the following document...

Страница 3: ...esult in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Attention Indicates a procedu...

Страница 4: ...upport ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support http support ge ip com Phone 800 1 433 2682 E...

Страница 5: ...Project to SD Card 22 3 5 Updating a Machine Edition Project 23 3 6 FTP Server 24 3 6 1 Authentication of Remote Users 24 3 6 2 FTP with Removable Flash Devices 24 3 7 HTTP Server 25 3 8 SNTP Server...

Страница 6: ...the Touchscreen 48 5 2 Keyboard 49 5 2 1 External Keyboard Optional 49 5 2 2 Soft Input Panel 49 5 3 Mouse 49 5 4 Memory 50 5 4 1 Dynamic RAM Memory 50 5 4 2 Modifying Memory Allocation 51 Appendix A...

Страница 7: ...ecifications Item IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx Processor Freescale i MX535 1 GHz ARM Cortex A8 Memory RAM DDR2 SDRAM 512 MB DDR3 SDRAM 1 GB ROM SLC NAND 256 MB SLC NAND 512...

Страница 8: ...GND internally 1 1 2 Physical Specifications and Mounting Options Item IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx Dimensions L W D 192 137 36 mm 7 56 5 39 1 42 in 278 222 65 mm 10 95 8 74...

Страница 9: ...torage Temperature 10 to 60 C 14 to 140 F Ambient Humidity Operating and Storage 85 RH Non condensing wet bulb temperature 30 C 86 F or less Environment Pollution Degree 2 Indoor use only Vibration Re...

Страница 10: ...Overview The following diagrams display the physical layout of the QuickPanel including locations of status LEDs communications ports and connectors Battery Cover COM USB Host Ports LAN Input Power SD...

Страница 11: ...tatus Indicator LED Touchscreen LCD SD Card USB Host Ports MICRO USB LAN2 COM1 LAN1 Input Power LINE OUT COM2 IC755CxS10CDx Hardware Features Introduction GFK 2847F User Manual 11 For public disclosur...

Страница 12: ...IC755CxS12CDx Hardware Features 12 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 13: ...ouchscreen LCD Status Indicator LED SD Card Input Power LINE OUT USB Host Ports MICRO USB COM2 LAN2 COM1 LAN1 IC755CxS15CDx Hardware Features Introduction GFK 2847F User Manual 13 For public disclosur...

Страница 14: ...starting Green solid Normal operating state Green blinking Backlight off Red blinking Backlight failure Off Power not applied to the unit 1 2 2 2 Ethernet Port LED Operation The Ethernet port has two...

Страница 15: ...te should such action be necessary For phone numbers and email addresses refer to the section Contact Information After unpacking the unit record all serial numbers Serial numbers are required if you...

Страница 16: ...er Connector Qty 1 Mounting Brackets Qty 4 Protective Sheet Qty 1 not shown Gasket Qty 1 not shown pre installed QuickPanel Operator Interface IC755CxW07CDx Example Package Contents 16 GFK 2847F Quick...

Страница 17: ...CAL SHOCK HAZARD To avoid personal injury or damage to equipment ensure that the dc supply is disconnected from power and that the leads are not energized before attaching them to the unit s power sup...

Страница 18: ...er cable is not energized 2 Loosen the screw clamps on the mating power connector 3 Strip the insulation from the power cables 4 Secure the power cable to the mating connector noting polarity and tigh...

Страница 19: ...om the Control Panel double tap Network and Dial up Connectionsto configure network settings 5 Run the Backup Utility to save the settings 2 4 Runtime Setup To download an application to a QuickPanel...

Страница 20: ...ickPanel To shut down the QuickPanel 1 Quit any programs that are running and wait for all file operations to complete 2 If you have not changed operating system settings for example brightness or tou...

Страница 21: ...ce The Backup Utility saves the changes made to the Windows Registry or Desktop to Flash Memory This is required because the QuickPanel is not battery powered Specifically the Backup Utility achieves...

Страница 22: ...card port 2 Double tap the Copy Project to SD Card icon on the desktop 3 Tap Yes when the Copy Project Query confirmation dialog box appears Caution Copying a project while the Proficy Machine Editio...

Страница 23: ...update If there is more than one flash device with a valid project copy present a Select Media confirmation dialog displays allowing you to choose which flash device to update with Select the device f...

Страница 24: ...of the flash device The server only supports anonymous login Anonymous with password requested but not validated This may prevent some types of attacks and is required by some clients Once connected...

Страница 25: ...n Note If the server status is changed the QuickPanel must be re booted before changes take effect 3 8 SNTP Server The SNTP server included with the QuickPanel supports SNTP Version 4 for IPv4 IPv6 an...

Страница 26: ...Notes 26 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 27: ...Installing the Protective Sheet To install the protective sheet 1 Remove the protective film on the screen of the QuickPanel 2 Wipe the display of any dust or fingerprints 3 Peel a corner of the clea...

Страница 28: ...o insert and remove the SD card cables and mounting brackets Choose a location that will allow natural convection air flow from bottom to top of the QuickPanel enclosure Do not mount the QuickPanel at...

Страница 29: ...screwdriver Mounting brackets supplied The IC755CxW07CDx IC755CxS10CDx and IC755CxS12CDx mounting holes are located on the top and bottom sides of the unit IC755CxW07CDx Mounting Holes IC755CxS10CDx...

Страница 30: ...The IC755CxS15CDx mounting holes are located on the top bottom and sides of the unit IC755CxS15CDx Mounting Holes 30 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 31: ...ted in the socket Caution When installing the QuickPanel into the panel pay careful attention while handling the unit so it does not drop and damage the unit To install the QuickPanel 1 Cut an opening...

Страница 32: ...the mounting hole as displayed in the following figure 5 Tighten the screws on the mounting bracket in a clock wise direction Torque Range for Mounting Clamp Screws Unit Torque Range IC755CxW07CDx 0 3...

Страница 33: ...the following figures The IC755CxW07CDx mounting holes attach with M4 screws that are 6 mm 0 24 in or less in length The IC755CxSxxCDx mounting holes attach with M4 screws that are 8 mm 0 32 in or le...

Страница 34: ...efore disposing of batteries Caution 1 Replacing the battery should only be performed by trained personnel and in a non hazardous location 2 If the QuickPanel Operator Interface is VESA mounted detach...

Страница 35: ...ATT 1 Remove the battery cover by pressing down while sliding outward IC755CxW07CDx Battery Cover Removal 2 Connect the battery harness connector to the header noting keyed orientation Battery Part Nu...

Страница 36: ...owing figure Do not let the harness connector go above the tab Harness Connector Orientation 5 Slide the battery cover into place taking care not to pinch the harness connector 36 GFK 2847F QuickPanel...

Страница 37: ...xSxxCDx only with battery part number IC755ACCBATTNL 1 Remove seven screws from the back cover IC755CxSxxCDx Screw Locations Back Cover 2 Gently press on either side tab to release the back cover Side...

Страница 38: ...5ACCBATTNL IC755CxSxxCDx Battery 4 Gently remove the coin battery and replace with a new one noting the polarity of the battery 5 Replace the battery cover and tighten all screws to 0 5 Nm 4 4 in lb 3...

Страница 39: ...ction Ethernet Port LED Operation The QuickPanel is equipped with 10BaseT 100 BaseTX Ethernet port s You can connect an Ethernet network cable unshielded twisted pair UTP CAT 5 to the unit through the...

Страница 40: ...et Mask and Default Gateway if applicable Note Run the Backup utility to save the settings 4 7 3 Serial Port 4 7 3 1 IC755CxW07CDx Serial Port Details A terminal block is supplied The mating terminal...

Страница 41: ...Nm 2 66 in lb Connectors Euro Terminal Tyco Electronics 284539 5 Mating Connectors Tyco Electronics 284510 5 4 7 3 2 1 Serial Port COM1 Interface RS 232 COM1 Pin Details Pin Signal Name Pin out 1 TXD...

Страница 42: ...ng DIP SW Bit ON OFF DIP SW Bit ON OFF SW2 1 OFF SW4 1 ON 2 OFF 2 ON 3 OFF 3 OFF 4 OFF 4 OFF 5 ON 5 ON 6 ON 6 ON 7 OFF 7 OFF 8 ON 8 OFF SW3 1 OFF SW5 1 OFF 2 ON 2 OFF 3 OFF 3 OFF 4 OFF 4 OFF 42 GFK 28...

Страница 43: ...witch Setting DIPSW Bit ON OFF DIPSW Bit ON OFF SW2 1 OFF SW4 1 ON 2 OFF 2 ON 3 ON 3 ON 4 OFF 4 ON 5 ON 5 ON 6 ON 6 ON 7 OFF 7 OFF 8 ON 8 OFF SW3 1 OFF SW5 1 OFF 2 ON 2 OFF 3 OFF 3 OFF 4 ON 4 OFF Inst...

Страница 44: ...require installation of the custom driver software Interface USB 2 0 Number of Ports Two Connectors Type A connector Maximum Supply Current 0 5 A per port Pin Signal Name Pin out 1 USB_VCC 2 USB_D 3 U...

Страница 45: ...vel 1 Vrms Pin Signal Name Pin out 1 GND 1 2 3 2 Lineout R 3 Lineout L 4 7 6 Audio MIC IN Details only applicable to IC755CxW07CDx Interface MIC IN monaural Number of Ports One Connectors 3 5 mm jack...

Страница 46: ...l 4 7 7 1 SD Card Storage Details Connectors SD card slot push in push out method Card support SD SDHC memory card Maximum capacity 32 GB Note During insertion observe the orientation of the SD card a...

Страница 47: ...could damage the touchscreen display 5 1 1 Adjusting the Display Brightness To adjust the brightness of the display 1 From the Control Panel double tap Display and select the Brightness tab to display...

Страница 48: ...el tab 3 Select Recalibrate Touch Screen 4 Select Recalibrate Touch Sensor Note During IC755CxW07CDx touchscreen sensor re calibration the user is prompted to activate a switch located in the battery...

Страница 49: ...d play 5 2 2 Soft Input Panel The Soft Input Panel SIP is a touchscreen version of a standard keyboard that may be used in place of a standard hardware keyboard An icon in the system tray enables the...

Страница 50: ...is not retained through a power cycle or reboot The split between program memory and storage memory can be adjusted as necessary to make more room for one or the other depending on your specific appli...

Страница 51: ...is displayed in the window The blue slider bar indicates the current amount of unallocated SDRAM and determines the boundaries within which the slider can move System Memory Slider Bar Note Storage m...

Страница 52: ...Notes 52 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 53: ...2 12 01 standard and CSA C22 2 No 213 M1987 Electromagnetic Compatibility Directive European Electromagnetic Compatibility EMC for Industrial Control Equipment Self declaration in accordance with Euro...

Страница 54: ...y GE Intelligent Platforms could void the user s authority to operate the equipment Industry Canada requires the following note to be published Note This Class A digital apparatus complies with Canadi...

Страница 55: ...ickPanel 10 Accessory Kit Replacement Mounting Clips Power and Serial Port Connectors IC755ACC10PRO QuickPanel 10 Replacement Screen Protectors Qty 3 IC755CSS12CDx QuickPanel 12 Color TFT with Multi t...

Страница 56: ...Notes 56 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 57: ...the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb Interface x1 RS 232 x1 RS 232 485 default is RS 485 Connectors Euro Terminal Tyco Electronics 1 284539 0 Mating Connector Tyc...

Страница 58: ...Notes 58 GFK 2847F QuickPanel Operator Interface User Manual For public disclosure...

Страница 59: ...lation 27 battery 34 guidelines 53 Installing panel mounting 29 protective sheet 27 IP Address 40 K Keyboard 49 external 49 SIP 49 L LED Operation status 14 M Machine Edition 22 updating a project 23...

Страница 60: ...l 49 Software 21 Specifications 7 environmental 9 general 7 physical and mounting 8 Startup 18 Status Indicators 14 Store Manager 21 T Touchscreen calibrating 48 display 47 U Universal Serial Bus USB...

Страница 61: ......

Страница 62: ...GE Intelligent Platforms 1 800 433 2682 1 434 978 5100 www ge ip com GFK 2847F For public disclosure...

Отзывы: