background image

To produce steam, the dryer must connect to 

the cold water supply. Since the washer must 

also connect to the cold water, a “Y” connector 

is inserted to allow both inlet hoses to make that 

connection at the same time.

NOTE: 

Use the new inlet hoses provided; never use 

old hoses.

1

.  Turn the cold water faucet off. Remove the 

washer inlet hose from the washer fill valve 

connector (cold).

2

.  Ensure the rubber flat washer is in place and 

attach one female coupling of the short hose 

onto the washer fill valve connector. Tighten by 

hand until firmly seated.

3

.  Attach one male end of the “Y” connector to the 

other female coupling of the short hose. Ensure 
the rubber flat washer is in place. Tighten by 
hand until firmly seated.

4

.  Insert the filter screen in the coupling of the 

washer’s

 inlet hose. If a rubber flat washer is 

already in place remove it before installing the 

filter screen. Attach this coupling to one male end 

of the ‘’Y’’ connector. Tighten by hand until firmly 

seated.

5

.  Ensure the rubber flat washer is in place and 

attach the 

dryer’s

 long inlet hose to one male 

end of the ‘’Y’’ connector. Tighten by hand until 

firmly seated.

6

.  Ensure the rubber flat washer is in place and 

attach the other end of the 

dryer’s

 long inlet 

hose to the fill valve connector at the bottom of 

the dryer back panel. Tighten by hand until firmly 

seated.

4

Installation Instructions

CONNECTING INLET HOSES

7

.  Using pliers, tighten all the couplings with an 

additional two–thirds turn.

NOTE:

 Do not overtighten. Damage to the couplings 

may result.

8.

  Turn the water faucet on.

9

.  Check for leaks around the ‘’Y’’ connector, faucet 

and hose couplings.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed 

within 42 in. (107 cm) of your washer’s water 

inlet. The faucets MUST be 3/4 in. (1.9 cm) garden 

hose-type so inlet hoses can be connected. Water 

pressure MUST be between 10 and 120 pounds 

per square inch. Your water department can 

advise you of your water pressure.

NOTE:

 A water softener is recommended to reduce 

buildup of scale inside the steam generator if the 

home water supply is very hard.

CONNECTING INLET HOSES  

(on some models)

CONNECTING INLET HOSES  

(on some models) 

(cont.)

Содержание GTD75ECSL1WS

Страница 1: ... Appliances at 800 GE CARES 800 432 2737 or visit our Web site at GEAppliances com Fire Hazard WARNING Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed a...

Страница 2: ...cessory WE25X20060 Complete Kit hoses Y adapter washers included OR WE1M847 Long Hose and WE01X22395 Short Hose PM14X10056 Dryer door opening vent brush not included WX14X10007 LintEater Dryer rotary tube brush not included 2 ROUGH IN DIMENSIONS 4 5 8 11 7 cm or 6 1 2 16 5 cm with Riser Y X 27 68 8 cm X 4 1 4 10 8 cm Side View Front View Cubic Foot X Y 6 2 43 3 8 110 cm 26 3 4 68 cm 7 2 43 3 8 110...

Страница 3: ...for electrical connection information REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION Explosion Hazard WARNING Keep flammable materials and vapors such as gasoline away from dryer Place dryer at least 18 46 cm above the floor for a garage installation Failure to do so can result in death explosion or fire The dryer MUST be vented to the outdoors See the EXHAUSTING THE DRYER section Minimum clearanc...

Страница 4: ...e the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated 4 Installation Instructions CONNECTING INLET HOSES ...

Страница 5: ...FF position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 10 Adjustable wrenches 2 8 Pipe wrench Flat blade screwdriver Level Slip joint pliers 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps 2 Safety glasses 4 dia metal duct recommended 4 Cover Plate Kit WE49X22606 4 dia UL list...

Страница 6: ...d ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI Z223 Explosion Hazard WARNING Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Securely tighten all gas connections If connected to LP gas have a qualif...

Страница 7: ... SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at the end of the dryer gas inlet Install a 3 8 flare union adapter to the female elbow IMPORTANT Use a pipe wrench to securely hold on to the end of the dryer gas inlet to prevent twisting the inlet NOT...

Страница 8: ... receptacle Ensure proper ground exists before use GROUNDING INSTRUCTIONS This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is p...

Страница 9: ...OFF THE TERMINAL BLOCK 9 MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 Strain relief UL recognized 4 Duct clamps 2 or 4 spring clamps 2 Safety glasses 4 dia metal duct recommended 4 Cover plate Kit WE49X22606 Gloves Exhaust hood Duct tape TOOLS YOU WILL NEED Slip joint pliers Flat blade screwdriver Phillips screwdriver Level 4 dia UL listed flexible metal duct if needed Dryer power cord kit not pr...

Страница 10: ...Failure to do so can result in death fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must ...

Страница 11: ... at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screw...

Страница 12: ...hat comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Kee...

Страница 13: ...will be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions and elbows of the system including the transition duct EXHAUST LENGTH 13 4 DIA 4 4 DIA 4 DIA 2 1 2 RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended No of 90 Elbows Rigid Metal Rigid Metal 120...

Страница 14: ...ance to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and dampened wall cap SEALING OF JOINTS All joints should be ti...

Страница 15: ...tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET TAB LOCATION Fire Hazard WARNING Disconnect dryer from electrical supply Wear gloves and arm guards Close the back opening with cover plate Kit WE49X22606 Failure to do so may result in fire electrical shock or lacerations Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about ...

Страница 16: ...HROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between the elbow and the bottom duct Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard Duct tape FINAL SETUP LEVEL THE DRYER Stand the d...

Страница 17: ...crewdriver Tape tipped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR MODELS 1 Open the door approximately 130 degrees With a putty knife remove the 4 plastic caps located along the left side of the front panel and set them aside 2 Remove the botto...

Страница 18: ...wer left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow these instructions swapping left and right When you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws Plastic Cap 4 Right side of front panel REVERSING THE DOOR con...

Страница 19: ...holes 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel Loosen each top hinge screw on right side B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 4 Remove both the blind plate and the strike plate and install them in the opposite positions 5 Remove the 4...

Страница 20: ...er back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Rotate the outer door 180 degrees mount the inner door back into the outer door frame and secure with the screws removed in step 5 Make sure you mount the hinges on the side opposite the pocket Install hinges from oposite sid...

Отзывы: