Problem
Possible Causes
What To Do
Salty tasting or
Unit not sanitized
•
Complete the
Sanitizing Procedures
on page 15.
brown/yellow colored
•
At completion of regeneration cycle (approx. 2 hrs), run water
water after installation
from faucets to purge the salty water.
Low water pressure
Check pressure.
•
Drain height 8
′
or less, pressure should be minimum of 20 psi.
•
Drain height above 8
′
, pressure should be minimum of 50 psi.
Restricted drain hose
•
Clean and reconnect drain line.
•
Check for kinks in drain line.
Brown/yellow
Unit was idle for a period of time
•
Complete the
Sanitizing Procedures
on page 15.
colored water
Sounds you might hear
Running water from the unit
•
This is normal. High water flows in backwash cycle, flushes
during regeneration
into a drain during regeneration
minerals and sediments from resin tank.
cycle
Harmonic noises during regeneration
•
This is normal.
Clicking
•
This is normal. This is the sound of various valves opening and
closing as valves cycle through regeneration cycle.
Water has air bubbles
Air in system after installation
•
Will go away after it runs for a while.
and is cloudy