![GE GLDT690T Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/ge/gldt690t/gldt690t_technical-service-manual_125942030.webp)
– 30 –
Caution:
The clamps are easily damaged during
removal and should not be reused.
12. Remove the 2 clamps, sump outlet hose, and
interconnect hose from the sump.
Note: Factory installed hose clamps are not
reusable. When installing a water inlet valve, drain
pump assembly, wash pump assembly, or sump
assembly, replace the old clamps with new screw-
type hose clamps provided. The screw-type hose
clamps are available separately.
Clamp Part Number
Size
WD01X10322
15/16" to 1-1/2"
Sump
Outlet
Hose
Interconnect
Hose
13. Remove the 2 Phillips-head screws that hold the
drain pump to the sump.
14. Rotate the pump 1/4-turn counterclockwise to
remove.