Check from the
J603
connecter on the board. Look
for approximately
12 VDC
from the
Red
wire pin 4 to the
Yellow
wire pin 1. And also
there should be approximately
7.5 VDC
from the
Brown
wire
pin 3 to the
Yellow
wire pin 1.
If either of these voltages are not
present, replace the inverter
board.
If they are present and the UI
board is not coming on, replace the
UI board.
Diagnostics From The Board
UI Logic Board Voltage
UI Board
96
Содержание GHWN8350DWS
Страница 1: ...Marcone 2014 MSA Training GE Mission 1 Top Load Washer 1 ...
Страница 6: ...HE Detergent Use Care recommends the use of HE detergent only ...
Страница 8: ...Warranty 8 ...
Страница 9: ...Warranty What GE will not Cover 9 ...
Страница 23: ...Basket and Tub Removal ...
Страница 28: ...Components Overview ...
Страница 29: ...Water Valves Three Different Water Valves Accommodates Three Different Dispenser Configurations ...
Страница 43: ...Squeeze the clamp until it snaps together Water Valves Reinstalling The Water Valve ...
Страница 44: ...Clamp Installed Water Valves Reinstalling The Water Valve ...
Страница 45: ...Water Valves Reinstalling The Water Valve Reinstall water valve to the top cover ...
Страница 57: ...Pressure Sensor Tub Water Level Hz conversion ...
Страница 76: ...76 Schematic Common Diagram to all Models ...
Страница 77: ...Schematic Strip Circuits Not Common to all Models Water Valves Neutral Supply 77 ...
Страница 78: ...Schematic Strip Circuits Not Common to all Models Water Valves Neutral Supply 78 ...
Страница 79: ...Schematic Strip Circuits Not Common to all Models Water Valves Neutral Supply 79 ...
Страница 80: ...Schematic Strip Circuits Not Common to all Models Bulk Tank Sensors 80 ...
Страница 82: ...Schematic Strip Circuits Not Common to all Models Tub Light 82 ...
Страница 83: ...Schematic Strip Circuits Not Common to all Models Recirculation Pump 120 AC Supply Neutral Supply 83 ...
Страница 84: ...UI Logic Board and RJ45 Board 84 ...
Страница 85: ...IMC Inverter Board J702 J701 J501 J407 J204 J1203 J101 J803 J502 J603 J1001 85 ...
Страница 101: ...Service Mode Tests ...
Страница 102: ...Service Mode Tests ...
Страница 103: ...Service Mode Tests ...
Страница 104: ...104 Fault Codes ...
Страница 105: ...105 Fault Codes ...
Страница 106: ...106 Fault Codes ...
Страница 107: ...Frequently Asked Questions ...
Страница 108: ...END OF PRESENTATION THANK YOU FOR YOUR ATTENTION 108 ...