Special Installation Requirements:
Installation: 
•  7" riser is included and the laundry pair can't be stacked
Alcove or Closet Installation: 
•  If your dryer is approved for installation in an alcove or closet, it will be  

stated on a label on the dryer back.

• The dryer MUST be exhausted to the outside.
•  Minimum clearances between dryer cabinet and adjacent walls or other  

surfaces are: 0" either side, 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
•  Closet doors must be louvered or otherwise ventilated and must contain a  

minimum of 60 sq. in. of open area equally distributed. If this closet contains  
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of  
open area equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with  

a gas dryer.

Bathroom or Bedroom Installation: 
• The dryer MUST be exhausted to the outdoors.
•  The installation must conform with the local codes, or in the absence of  

local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223.

Minimum Clearance other than Alcove or Closet Installations: 
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories,  

please call 1-800-GE-CARES.

For answers to your Monogram,

®

 Cafe

 Series 

or

 

Profile

 Series appliance questions, visit 

our website at geappliances.com or call GE 

Answer Center

®

 service, 800.626.2000.

Specification Revised 5/13

360500

GFWR4800F/4805F 

GE

®

 ENERGY STAR

®

 4.8 DOE cu. ft. capacity RightHeight

 Design Front Load washer

 