GE GEWADREW5001 Скачать руководство пользователя страница 12

EXHAUSTING THE DRYER (cont.)

NEVER LEAVE THE BACK OPENING WITHOUT THE 

PLATE. 

(Kit WE1M454.)

Installation Instructions

SIDE OR BOTTOM VENTING (cont.)

Connect standard metal elbows and ducts to 

complete the exhaust system. Cover back opening 

with a plate (Kit WE1M454) available from your  

local service provider. Place dryer in final location.

ADDING COVER PLATE TO REAR OF CABINET

ADDING ELBOW AND DUCT FOR EXHAUST TO 

LEFT OR RIGHT SIDE OF CABINET (cont.)

Plate  

(Kit WE1M454)

 

Apply duct tape as 

shown on the joint 

between the dryer 

internal duct and the 

elbow, and also the joint 

between the elbow and 

the side duct.

Use 4” rigid metal ducting only inside the dryer. 

Internal duct joints must be secured with tape, 

otherwise they may separate and cause a safety 

hazard.

12

DUCT
TAPE

ADDING ELBOW FOR EXHAUST THROUGH 

BOTTOM OF CABINET

•   Insert the elbow through the rear opening and 

connect it to the dryer internal duct.

 

Apply duct tape as 

shown on the joint 

between the dryer 

internal duct and the 

elbow, and also the 

joint between the 

elbow and the bottom 

duct.

Internal duct joints must be secured with tape; 

otherwise, they may separate and cause a safety 

hazard.

Duct tape

FINAL SETUP

 LEVEL THE DRYER

Stand the dryer upright near the final location and 

adjust the four leveling legs at the corners to ensure 

that the dryer is level from side to side and front to 

rear.

Lower

Raise

 

PLUG DRYER IN

1

2

 DRYER START-UP

Press the 

Power

 button.

Power

NOTE:

 If the dryer has been exposed to 

temperatures below freezing for an extended 

period of time, allow it to warm up before pressing 

Power

. Otherwise, the display will not come on.

The dryer is now ready for use.

3

Ensure proper 

ground exists 

before use.

Содержание GEWADREW5001

Страница 1: ...ryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting the Dryer to House Vent later in this manua...

Страница 2: ... hours a day or by phone at 800 626 2002 during normal business hours Part Number Accessory WE25X20060 Complete Kit hoses Y adapter washers included OR WE1M847 Long Hose and WE01X22395 Short Hose PM14X10056 Dryer door opening vent brush not included WX14X10007 LintEater Dryer rotary tube brush not included POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord ...

Страница 3: ...ust vent Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room See the sections for electrical connection information If the dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See the EXHAUSTING THE DRYER section Minimum clearance between dry...

Страница 4: ...e the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated 4 Installation Instructions CONNECTING INLET HOSES ...

Страница 5: ... TERMINAL BLOCK Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spring clamps 2 Safety glasses 4 dia metal duct recommended 4 dia UL listed flexible metal duct if needed Gloves Exhaust hood Duct tape Dryer power cord kit not provided with dryer UL rated 120 240V 30A...

Страница 6: ...fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet...

Страница 7: ...e electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of t...

Страница 8: ...tion duct maximizing drying performance Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the home exhaust vent using flexible metal foil type transition duct UL LISTED universal flexible dryer transition duct GE parts PM8X73 or WX8X73 may be used ONLY in installations where rigid metal or...

Страница 9: ... will be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions and elbows of the system including the transition duct EXHAUST LENGTH 9 DO NOT bend or collapse ducting Use elbows if turns are necessary DO NOT use excessive exhaust length Cut duct as short as poss...

Страница 10: ...uld present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and dampened wall cap SEALING OF JOIN...

Страница 11: ...w to the dryer internal duct Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical supply Wear gloves and arm guards Failure to do so may result in fire electrical shock or lacerations Through the rear opening locate the tab in the middle of th...

Страница 12: ...afety hazard 12 DUCT TAPE ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between the elbow and the bottom duct Internal duct joints must be secured with tape otherwise they may separate and cause a safety haza...

Страница 13: ...pped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR MODELS 1 Open the door approximately 130 degrees With a putty knife remove the 4 plastic caps located along the left side of the front panel and set them aside 2 Remove the bottom screw from each ...

Страница 14: ...ed in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow these instructions swapping left and right When you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws Plastic Cap 4 Right side of front pane...

Страница 15: ...n the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 4 Remove both the blind plate and the strike plate and install them in the opposite positions 5 Remove the 4 door hinge screws 6 inside screws and 2 pocket screws Lift the inner door upwards using a...

Страница 16: ...or Rotate outer door 180 Inside screw Inside screws Pocket screws Inside screw Door hinge screws Inside screw Inside screw B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 8 Mount the assembled door on the 2 upper left side hinge screws installed in step 2 Move the hinge screws loosened in step 2 into the lower left side screw holes and firmly tighten all 4 screws 9 Install the 4 plastic caps rem...

Отзывы: