2 Safety Measures & Warning

• The GEP inverter strictly conforms and has been tested according to international safety 

regulations. 

• The manufacturer strongly advises installers to follow local safety regulations during 

commissioning, operation and maintenance of the GEP inverter. Improper operation may result in 
electric shocks or damage to equipment and property.

• The installation, maintenance and connection of the inverters must be performed by qualified 

personnel, in compliance with local electrical standards, regulations and following the regulations 
of the local power suppliers, companies and related authorities. 

•  If the GEP inverter is unpacked but not put into use immediately,  please put it back to the original 

package with the desiccant bag and seal it with tape.

• To avoid electric shocks, the DC input and AC output port of the inverters must be disconnected 

for at least 5 minutes before performing any installation or maintenance.

• The temperature of some components of the inverters may exceed 60

 during operation. To 

avoid burns, do not touch the inverter during operation. Let the inverter cool before operating.

• Keep children away from the inverter. 
• Touching or changing inverter components without following manual instructions may cause 

personal injury, damage the inverters and could ultimately invalidate the warranty.

• The electronic components of the inverter could be damaged by static electricity. Appropriate 

methods must be adopted to prevent such damage, otherwise the warranty may be null and void. 

• Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage 

of the inverter, otherwise the inverter may be damaged and the warranty may be null and void. 

• When exposed to sunlight, the PV array generates dangerously high DC voltage. We strongly 

advise operators strictly follow instructions and avoid actions that put lives at risk. 

• The PV modules should have as a minimum an IEC61730 class A rating protection. 
• If the equipment is used in a way not authorized by the manufacturer, the equipment built-in 

protections may be damaged. 

• In order to achieve complete equipment isolation: turn off the AC switch first, then turn off the DC 

switch.

• Do not insert or pull the AC or DC terminals when the inverter is in operation.  
• An Arc Fault Detector is recommended to be installed on the DC side of an earthing photovltaic 

system.

• The inverter can exclude the possibility of DC residual currents to 6mA in the system, Where an 

external RCD is required in addition to the built-in RCMU, type A RCD must be used to avoid 
tripping. 

• The PV is not grounded as default configuration. 

Failure to observe a warning indicated in this manual may result in 

injury.

Danger of high voltage & electric shock.

This side up. The package must always have the arrows point up.

Special disposal instructions.

Refer to operation instructions

.

CE mark.

1 Symbols

Don't touch, hot surface!

No more than four  identical packages stacked on each other.

Fragile.

Wait at least 5 minutes after disconnecting the inverter before 

handling internal parts

.

Keep Dry.

Recyclable materials.

4

5min

01

02

Содержание GEP10S

Страница 1: ...33 support au gesolarinverter com sales au gesolarinverter com Global Sales Service Network GEP 4 6 10KW SINGLE PHASE USER MANUAL GE is a registered trademark of General Electric Company and is used under license by Jiangsu GoodWe Power Supply Technology Co Ltd 2020 All Rights Reserved 340 00468 02 ...

Страница 2: ...al Connection 08 4 4 Communication Connection 12 5 System Operation 16 5 1 LCD Panel 16 5 2 User Interface and System Configuration 17 5 3 Wi Fi LAN Reset Wi Fi LAN Reload 22 5 4 Precaution for Initial Startup 22 5 5 Special Adjustable Setpoints 23 6 Troubleshooting 26 7 Caution 28 7 1 Checking The DC Switch 28 7 2 Checking The Electrical Connection 28 8 Technical Parameters 29 TABLE OF CONTENTS ...

Страница 3: ...ed to prevent such damage otherwise the warranty may be null and void Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty may be null and void When exposed to sunlight the PV array generates dangerously high DC voltage We strongly advise operators strictly follow instructions and avo...

Страница 4: ...ty extension solution for our customer For further details please visit www gesolarinverter com Item 1 2 3 4 5 6 7 8 9 Name DC Switch PV Input Terminal Wi Fi LAN Module Optional DRED Function Optional CT and RS485 Optional AC Output Terminal LCD Display Indicator Lights Buttons Description During normal operation it is in on state and it can shut down the inverter after the inverter is disconnecte...

Страница 5: ... be installed near flammable and explosive items Strong electro magnetic charges should be kept away from installation site 4 Product label and warning symbols should be located and placed in a manner that can be easily ready by users 5 Ensure the inverter is installed in a location that is protected from direct sunlight rain and snow Accmulated snow Keep away from sunlight Keep dry Keep it clear ...

Страница 6: ...y Grade A B C D Description Outside diameter Separated wire length Conductor wire length Conductor core section Value 13 18mm 20 25mm 7 9mm 2 5 10mm2 D A B Annealed copper wire C Cables Screw cap AC sheet cover Single hole seal ring The insulator Inverter GEP4 6 1C 10 GEP5 0 1C 10 GEP7 0 1 10 GEP8 5 1 10 GEP9 0 1 10 GEP10 1 10 Conductor core section 2 5mm2 4mm2 10mm2 4 3 Electrical Connection 4 3 ...

Страница 7: ... PE wire ground wire Not following this instruction may cause damage to the inverter 5 Red wire represents positive black wire represents negative 6 For the GE series the minimum insulation resistance to the ground of the PV panels must exceed 20kΩ R 600 30mA There is risk of electric shock if this minimum resistance requirement is not met Inverter Model GEP4 6 1C 10 GEP5 0 1C 10 GEP7 0 1 10 GEP8 ...

Страница 8: ...ed metal parts of the equipment and other enclosures in the PV power system must be grounded Please follow the steps below to connect PE cable to ground L1 L2 L1 1 2mm Step 1 Strip the wire insulation sheet of a suitable length with a wire stripper Step 2 Insert the stripped wire into the terminal and compress it tightly by crimping pliers Step 3 Fix the earth wire In order to improve the corrosio...

Страница 9: ...d installations in compliance with Australian and New Zealand safety requirements and DRED is not provided by the manufacturer DRED should be connected to the COM port with 6 Pin as illustrated below Please connect the cables in order as shown in the right table CT Power Limit Device and RS485 communication ports are optional based on the demand of the clients Function CT CT NO 5 6 CT Function RS4...

Страница 10: ...tion of commu nication connection you can access portal gesolarinverter com or download the Power Sight App by scanning the QR code to monitor your PV plant and device Please contact after sales for further details 4 4 4 Export Power Limit Connection Diagram The methods of connecting the Power Limiting device CT is shown below For the detailed installation procedure of CT please refer to Step 4 of...

Страница 11: ... 6000W Or Or Power Limit ON Pac 6000W Power Limit OFF Pac 6000W Set Power Limit XXX Set Power Limit XXX Set Modbus Addr Pac 6000W Short Press Long Press Short press short press to select Leading or Lagging Short Press to select number 8 or 9 Short Press to select number 0 9 Short Press to select number 0 9 Long Press Disable Lagging 0 95 Lagging 0 95 Lagging 0 95 Long Press Wait W L Reloading W L ...

Страница 12: ... E Today menu which displays the total power generation for today Short press the button to enter the E Total menu which displays the total power generation up to today Short press the button to enter the menu which displays the PV1 voltage in V and current in A Short press the button to enter the menu which displays the PV2 voltage in V and current in A Short press the button to enter the menu wh...

Страница 13: ... Set Power Limit XXX Long press 2S 6 Operation of display under grid connected mode When the input voltage reaches the inverter s start up voltage the LCD starts to work the yellow light will be turned on and the LCD will display Waiting More information will be displayed within a few seconds If the inverter is connected to the grid Checking XXs will be displayed and a countdown will commence from...

Страница 14: ...specifically according to the inverter Modbus address and Modbus register value according to the set range to set the corresponding value PF Power Curve Mode Function PF curve mode enable or disable B P Prated C Power factor Default value Australia 0 50 50 0 9 Default value New Zealand 0 50 50 0 9 Setting range 0 or 1 30 80 0 8 1 Register 40600 40603 40606 V1 V2 V3 V4 V1 V2 V3 V4 100 80 60 40 20 0...

Страница 15: ...e refer to the following instructions before contacting your local service If any problems arise the red FAULT LED indicator on the front panel will light up and the LCD screen will display relevant information Please refer to the following table for a list of error messages and associated solutions 1 Disconnect DC switch take off DC connector check the impedance between PV PV to earth 2 If impeda...

Страница 16: ...t s possible that there are special characters not supported by the module in the hotspot password Please modify the password so that it consists of only Arabic numerals or uppercase lowercase letters 2 If the problem still persists contact local service office for help 7 Caution 7 1 Checking The DC Switch DC switch does not require any maintenance It is recommended though not compulsory to Check ...

Страница 17: ...120 360 80 600 0 13 13 13 16 3 16 3 16 3 3 1 1 1 4600 4600 230V 50 20 3 150 120 80 97 7 97 3 GEP7 0S 13500 600 80 550 80 120 360 80 600 0 13 13 13 16 3 16 3 16 3 3 1 1 1 7000 7000 230V 3 50 1 35 1 Adjustable from 0 8 leading to 0 8 lagging 3 150 120 80 97 6 97 2 Integrated Integrated Integrated Integrated Type Ⅱ Integrated Type Ⅱ Integrated Integrated Integrated Integrated Class Ⅰ C 25 60 0 100 40...

Страница 18: ...res Moisture Location Category Definition Environment Category Definition Outdoor the ambient air temperature is 20 50 Relative humidity range is from 4 to 100 applied to PD3 Indoor unconditioned the ambient air temperature is 20 50 Relative humidity range is from 5 to 95 applied to PD3 Indoor conditioned the ambient air temperature is 0 40 Relative humidity range is from 5 to 85 applied to PD2 Po...

Отзывы: