8�2�2 Inverter Parameter Introduction
Parameters
Description
Normal
Home page. Indicates the real-time power of the inverter. Long press
for 2s to check the current safety code.
E-Today
Check the generated power of the system for that day.
E-Total
Check the total generated power of the system.
Vpv
Check the DC input voltage of the inverter.
Ipv
Check the DC input current of the inverter.
Vac
Check the voltage of the utility grid.
Iac
Check the AC output current of the inverter.
Fac
Check the frequency of the utility grid.
Error History
Check historical error message records of the inverter.
Model
Indicates the specific inverter model. Long press for 2s to set the
safety code. Set the safety country in compliance with the local grid
standards and application scenario of the inverter.
Ver
Check the software version.
Set Language
Set language accordingly. Languages: English, Portuguese, Spanish。
Set Time
Set time according to the actual time in the country/region where the
inverter is located.
RSSI
Indicates the received signal strength of the GPRS module and 4G
module.
W/L Reset
Power off and restart the WiFi module.
W/L Reload
Restore the factory settings of the WiFi module. Reconfigure the WiFi
module network parameters after restoring the factory settings,
PF Adjust
Set the power factor of the inverter according to actual situation.
Time Interval
Set Time Interval according to actual needs.
Shadow MPPT
Enable the shadow scan function if the PV panels are shadowed.
Short press
Short press
Short press
Short press
Short press
Short press
USB Mode Select
Set OK
Set Fail
Host Mode
Device Mode
Fault Clear
ARC Disable
Self Check
Set OK
Set Fail
ARC Enable
Set ARC
Pac = xxx W
Long press for 2s
Long press for 2s