P/N 1069682 • REV 1.0 • ISS 14APR10 

3 of 9 

 

Wiring Technical Notes 

These technical notes should all be considered prior to installing these devices. 

•  Use point to point unshielded twisted pair wire 24-16 AWG (0, 5-1, 3 mm) 

stranded or solid, Category 2 or better. 

•  The video signal may coexist in the same wire bundle as other video, 

telephone, data, control signals, or low-voltage power. You can run GE video 
signals in or near electromagnetic fields (in accordance with National 
Electrical Code, local or other local safety requirements). 

•  DO NOT USE SHIELDED TWISTED PAIR WIRE. Multi-pair (8 pair or more) wires 

with an overall shield are fine. 

•  DO NOT USE UN-TWISTED WIRE. 

•  DO NOT place a transmit and a receive signal in the same wire bundle. It 

may cause interference. 

•  DO NOT send 

Up-the-Coax

 Pan/Tilt/Zoom signals through active (amplified) 

GE transmitters or receivers. Passive GE transceivers can transmit video and 

Up-the-Coax

 P/T/Z control signals up to 750 ft. (228 m). 

•  We recommend using short 18 AWG solid wires for ground connections. 

•  GE VPD products follow the EIA/TIA 568 standard. There are two wire color-

code standards: EIA/TIA 568A and EIA/TIA 568B. Either standard can be used 
for making connections as long as the RJ-45 jacks at both ends of each 
cable follow the same standard. 

•  Measure wire distance by: 

1.  Shorting the two conductors together at the far end, and measuring 

the loop-resistance by an Ohmmeter.  

2. Use 

the 

Loop Resistance

 table to calculate the distance. 

•  DO NOT connect coax cables longer than 100 ft. (30 M) to the BNC 

connectors of any GE UTP equipment. 

•  All measured distances should include any coax cables in the path. 

•  Verify camera current requirements and wire resistance limits for the 

maximum distance that power can travel. Use the 

Power Distance Chart

 to 

verify the wire distance. 

•  GE VPD products require Unshielded Twisted-Pair (UTP) wires Category 2 or 

better, 24 AWG (0,5 mm) or thicker. 

Содержание GEC-16VPHUB

Страница 1: ...desk or rack mounted They use Category 2 7 twisted pair wires and do not require power They provide built in surge suppression to protect video equipment against damaging voltage spikes and provide noise immunity to ensure quality images The included RJ 45 adapter provides an easy way to connect the passive hubs to other GE VPD products via Cat 5 cables and RJ 45 connectors These passive hubs are ...

Страница 2: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Страница 3: ...ivers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the EIA TIA 568 standard There are two wire color code standards EIA TIA 568A and EIA TIA 568B Either standard can be used for making connections as long as the RJ 45 jacks at both ends of each cable foll...

Страница 4: ... ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Important Safety Warnings Installation should be made by a qualified service person and should conform to all local codes DO NOT bundle UTP signals in the same conduit as high voltage wiring To reduce the risk of fire or electrical shock do not expose these products to rain moisture dripping or splashing No...

Страница 5: ...nnect to the transceiver hub Make sure that the same UTP pair and polarity are used on both the transmit and receive sides Video Connect the baseband Video signal output of the camera to the BNC of the Transceiver Control Room Installation UTP Connect the UTP wires carrying video signals to the terminal block input of the receiver hub If the UTP is terminated with a RJ 45 connector then use either...

Страница 6: ...w connector to a qualified earth ground using a short thick wire If the picture is scrambled change the polarity of the twisted pair wires on the corresponding terminal block Technical Specifications Electrical Video Format NTSC PAL SECAM Frequency 20 Hz to 6 MHz Coax 75 Ohm Input Current 2 4 A at 115 VAC 1 2 A at 230 VAC GEC 8PVPDTCHUB 4 8 A at 110 VAC 2 4 A at 220 VAC GEC 16PVPDTCHUB Twisted Pai...

Страница 7: ... 16VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm GEC 32VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm Weight GEC 4VPHUB 0 2 lb 90 g GEC 8VPHUB 3 3 lb 1500 g GEC 16VPHUB 3 3 lb 1500 g GEC 32VPHUB 3 3 lb 1500 g Environmental Humidity 0 to 95 noncondensing Temperature Operating 10 to 50 C Storage 30 to 70 C Specifications are subject to change without notice Included Accessories GEC 4VPHUB RJ 45 Adapter Include...

Страница 8: ... 9 P N 1069682 REV 1 0 ISS 14APR10 EIA TIA 568A B Color Codes Midspan Control Room Data Connections GEC 4VPHUB Cameras 1 4 GEC 8VPHUB GEC 16VPHUB GEC 32VPHUB Cameras 1 8 GEC 16VPHUB GEC 32VPHUB Cameras 9 16 ...

Страница 9: ... interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receive...

Отзывы: