Turbidity Sensor - Calibration
Failure of the turbidity sensor will result in maximum wash/rinse cycles.
When a main control board is replaced, it
will automatically start a “factory test
mode” During that cycle, the turbidity
sensor will be calibrated.
If a turbidity sensor is replaced w/o
replacing a control, the turbidity sensor
can be calibrated by doing the following:
1. Open the door and press the
Start/Reset pad 100 times.
2. That will flag the board to calibrate the
sensor during the next full dishwasher
cycle.
Содержание GDWT668V
Страница 2: ...2 Presenter and Event 8 2 2011...
Страница 3: ...3 Presenter and Event 8 2 2011...
Страница 6: ...6 Presenter and Event 8 2 2011 Monogram Cafe Profile GE...
Страница 15: ...15 GE Title or job number 8 2 2011 Lower rack roller Roller locks onto rack Spread roller tabs outward...
Страница 32: ...32 GE Title or job number 8 2 2011 Drain Pump Check valve removed by simply pulling forward Outlet check valve...
Страница 34: ...34 GE Title or job number 8 2 2011 10 F Start capacitor Mounted with 1 screw Motor Assembly...
Страница 35: ...35 GE Title or job number 8 2 2011 Heater Heating Element connections in rear of machine 16 resistance value...
Страница 37: ...37 GE Title or job number 8 2 2011 Door...
Страница 40: ...40 GE Title or job number 8 2 2011 New Look Inner Door Panel...
Страница 44: ...44 GE Title or job number 8 2 2011 Remove 2 Phillips head screws for HMI control H M I Control...
Страница 47: ...47 GE Title or job number 8 2 2011 Outer Door Panel Handle Removal Full length view...
Страница 50: ...50 GE Title or job number 8 2 2011 Door Switch Door switch is held in place with 3 Phillips head screws L1 N...
Страница 72: ...72 GE Title or job number 8 2 2011...