GE Energy Gas Turbines

Mechanical Drive — Two Shaft Version.

The GE10-2 is the two shaft version of the GE10
intended for mechanical drive applications. The turbine
consists of four reaction stages. The first two stages or
High Pressure Turbine which are used to drive the axial
compressor are common with the GE10-1 model. The low
pressure shaft is a double stage, high-energy turbine with
variable first stage nozzles which provide maximum
flexibility for mechanical drive applications. These third and
forth stages which make up the Low Pressure Turbine are
coupled to the power shaft driving the load. They are
cooled by air bled from the axial compressor.

COMBUSTOR

The combustion system consists of a single, slot-cooled
combustion chamber assembly that permits quick and
easy maintenance of the hot gas path. This combustion
chamber is able to burn a wide range of fuels including
liquid distillates, residuals and all gaseous fuels including
low BTU gas with system modifications.
The GE10 combustion system is available in both
conventional and DLE configurations. The DLE (dry low
emissions) system is a simple, field-proven design that
guarantees operation at 25 ppmv NOx (burning Natural
Gas). The GE10 can also utilize steam and water
injection for NOx reduction and power augmentation.
Further reduction of emission levels is a constant
objective of our continuing combustion development
and test programs.

AUXILIARIES

The integrated lubrication system (including oil tank)
that feeds the gas turbine, the speed reduction gear and
the electric generator is located on the turbine base
plate. The main lube oil pump is mechanically driven by
the gearbox. An AC electric motor-driven pump
guarantees lubrication during normal operation while a

DC electric motor-driven pump is provided for
emergency backup. In the standardized package
configuration the oil is cooled by an air cooler. A water
cooler can be provided upon customer request. 
The thrust and journal bearings are of the tilting pad type. 
The starting system consists of a V.F.D. motor drive for the
single shaft  version. 
The twin shaft can be equipped with a torque converter
plus electric motor or starting expansion turbine.
The GE10 control system has been implemented to
assure a high degree of integration and standardization
between the engine and the turbine generator package.
Programmable modules guarantee easy
implementation of any control and protection scheme
to tailor the control system to the application and
customer needs.

PACKAGE

The package designed for power generation
applications is optimized to minimize plant dimensions
and to reduce maintenance cost and time. In the
standard configuration, the speed reduction gear is
mounted on the gas turbine base plate. The auxiliaries
are installed on a separate base plate permanently
joined to that of the gas turbine base plate to form a
single lift on which the sound-insulated enclosure is
mounted.
The electric generator is installed on a concrete
foundation to limit the shipping dimensions. The overall
length of the genset is about 13 m.
The other modules completing the system are the
oil/air exchangers, the air intake filter chamber, the
suction duct  (vertical suction) and the exhaust system
(axial exhaust).
The enclosure has a sound pressure level lower than 85
dBA at 1 m. This acoustic design meets ISO NR 50 limits
at 100 m. 

Содержание Gas Turbine

Страница 1: ...Gas Turbines GE Energy Oil Gas...

Страница 2: ...25 LM6000 Main Components Axial Compressor First Stage Nozzles Buckets and Wheels Gas Turbine Operability LNG Exploration and Production Floating Production Units Pipeline Refinery and Petrochemicals...

Страница 3: ...U S A to complement the existing portfolio of products for the petroleum and petrochemical industries reciprocating and centrifugal compressors gas engines pumps valves etc A proven combination of so...

Страница 4: ...the first stage nozzles and buckets to enable higher firing temperatures and enhanced efficiency The LP turbine of the twin shaft version has two stages The new GE5 is a compact state of the art 6 MW...

Страница 5: ...power range COMBUSTOR The GE5 uses an annular combustor architecture to achieve the maximum efficiency while maintaining the highest reliability standards The unit is configured with a DLE combustion...

Страница 6: ...e lube oil cooler and the generator The entire GE5 1 package is compact with a footprint of only 5810 mm L x 2500 mm W providing the user with the flexibility to locate the system indoors or near pre...

Страница 7: ...of the best of both types of engines This provides customers with the benefit of a variety of cost effective service programs e g condition based maintenance site based or exchange engine programs an...

Страница 8: ...sor is a high performance eleven stage axial flow design with a 15 5 1 pressure ratio operating under transonic flow conditions derived from GE Aircraft Engine aero derivative technology The first thr...

Страница 9: ...ne base plate The main lube oil pump is mechanically driven by the gearbox An AC electric motor driven pump guarantees lubrication during normal operation while a DC electric motor driven pump is prov...

Страница 10: ...essor discharge air The MS5001 Gas Turbine is the ideal solution for power generation where low maintenance reliability and economy of fuel utilization are required Low operating and investment costs...

Страница 11: ...or service shop assistance The main features of its design are High pressure shaft consisting of a 16 stage 17 for MS5002D axial flow compressor and a single stage high energy turbine The first stage...

Страница 12: ...ity the MS5002E has a conservative firing temperature with respect to the state of the art High efficiency was achieved through the use of advanced design tools to optimize airfoils clearances leakage...

Страница 13: ...needed A predecessor of the 7FA the 7EA is ideal for plants that require high efficiency along with shaft speed for direct coupling to the generator 13 GE Energy Gas Turbines MS6001B MS7001EA MS9001E...

Страница 14: ...tions the PGT16 synchronously coupled to a generator with a speed reduction gear is a highly flexible turbogenerator which can be operated as a simple cycle or in combined or cogeneration cycle applic...

Страница 15: ...the blading assembly has a cobalt base for the nozzles and a nickel base for the rotor blading i e the same materials used on heavy duty gas turbines A large creep and fatigue LCF HCF safety margin on...

Страница 16: ...efits contributing to PGT25 customer value Specialized aeroderivative annular combustion chamber fuel nozzles makes the PGT25 ideal for a wide range of mechanical drive gas pipeline etc power generati...

Страница 17: ...g the tradition of the established record of GE s LM2500 the LM6000 is ideal as a source of drive power for pipeline compression offshore platform and gas re injection as well as for LNG compressors T...

Страница 18: ...internal damping characteristics The large chord broad blade compressor blades have low stresses and the unique ability to withstand damage by small foreign objects as well as to maintain high perform...

Страница 19: ...is directed through the body of the individual nozzle partitions and out holes near the trailing edge This not only cools the metal but blankets the trailing edge with a film of air Additionally relat...

Страница 20: ...ure that the gas generator shaft speed is always at the design value thereby ensuring maximum output The MS5002D instead uses variable nozzle guide vanes to maintain maximum output on the standard mod...

Страница 21: ...ement have already been proven in the field as shown in the following figure relating to the test of a GE10 2 unit at various free power turbine speeds Thanks to the application of CPC logic it has be...

Страница 22: ...nes as drivers GE Energy provides a complete range of mechanical drive gas turbines that are ideally matched to Oil Gas applications The extensive use of the GE MS6001 and MS7001EA single shaft gas tu...

Страница 23: ...turbine and pipeline compressor lines Direct compressor turbine couplings improve the reliability and efficiency of gas turbine compressor units reducing the spares inventory Compact integrated turbin...

Страница 24: ...d the advantages of a single source of supply fully integrated auxiliary systems and high operational flexibility and reliability Typical applications include Process air centrifugal compressor drive...

Страница 25: ...chanical data and computing in real time Test facilities include a high pressure feed system for gas mixtures inert and flammable gases a gas chromatograph for gas analysis a 60 Hz generator low and h...

Страница 26: ...not limited to mechanical engineering We have developed business solutions such as remote monitoring diagnostics to help drive customer value by providing higher equipment reliability availability and...

Страница 27: ...machinery and equipment actually installed at their sites Traditional training tools are augmented with computer based training and interactive multimedia technology Courses and technical literature...

Страница 28: ...00 482 900 PGT16 13 720 10 300 35 0 20 2 47 3 104 3 7 900 491 919 PGT20 17 464 10 238 35 2 15 7 62 5 137 7 6 500 475 887 PGT25 22 417 9 919 36 3 17 9 68 9 151 9 6 500 525 976 PGT25 30 226 9 084 39 6 2...

Страница 29: ...47 3 104 3 7 900 491 919 PGT20 18 121 24 300 9 867 6 975 36 5 15 7 62 6 137 9 6 500 475 887 PGT25 23 261 31 193 9 560 6 759 37 7 17 9 68 9 151 9 6 500 525 976 PGT25 31 364 42 060 8 754 6 189 41 1 21...

Страница 30: ...1 x 3 5 x 3 5 37 650 9 1 x 3 5 x 3 5 37 650 9 1 x 3 5 x 3 5 37 650 9 1 x 3 5 x 3 5 30 750 6 5 x 3 6 x 3 9 30 750 6 5 x 3 6 x 3 9 31 000 9 3 x 4 2 x 4 4 31 000 9 3 x 4 2 x 4 4 87 430 11 6 x 3 2 x 3 7...

Страница 31: ...ovo Pignone S p A via F Matteucci 2 50127 Florence Italy T 39 055 423211 F 39 055 4232800 www geoilandgas com COMK MARK 769 II Designed by Studio Tre Fasi Printed by Sagraf 7 2005 2005 Nuovo Pignone S...

Отзывы: