background image

FTP-1000

Installation Manual

10

Appendix A

Specifications and notices

Note:  

See specific panel installation instructions for complete UL installation requirements for the system you are installing.

Radio interferance information to the user

If this equipment causes harmful interferance to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interferance by one or more of the 
following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits.

Consult the dealer or an experienced radio/TV technician help.

Table 4.

Specifications

Specification

Rating

Compatibility

Concord, Concord Express, Concord Ultra, Concord 4

Power requirements

12 VDC nominal, 75 mA

Temperature range

32 to 120°F (0 to 49°C) Operating
-30 to 140°F (-34 to 60°C) Storage

Maximum humidity

85% relative, noncondensing

Dimensions

5 in. x 4.50 in. x 0.75 in. (L x W x D)

UL/cUL listings

UL (985, 1023, 1610)
cUL (C1023 - 1974, S545 - M89)
For cUL listed applications, the unit shall be installed in accordance with 
Part 1 of the Canadian Electrical Code.

Содержание FTP 1000 - Security Concord LCD Touchpad

Страница 1: ...A B 1 2 3 4 5 6 7 8 9 0 Stay Away Disarm Quick Exit C D FTP 1000 Touchpad Display Installation Manual ...

Страница 2: ...marks and patents GE and the GE monogram are registered trademarks of General Electric FTP 1000 touchpad display product and logo are registered trademarks of GE Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Intended use Use this product only for the purpose it was designed for refer to the dat...

Страница 3: ...lication library on page 9 for instructions on accessing our online publication library Note A qualified service person complying with all applicable codes should perform all required hardware installation Conventions used in this document The following conventions are used in this document Safety terms and symbols These terms may appear in this manual Bold Menu items and buttons Italic Emphasis o...

Страница 4: ...liary panic buttons that can be activated anytime A built in speaker provides alarm status and button press sounds A swing down door reveals a label with basic system operating commands The door can be removed by simply opening it past its stop point The door can also be reattached later if desired Tools and equipment needed 4 conductor 22 or 18 gauge wire Screwdriver 6 screws and anchors included...

Страница 5: ...owed between the touchpad and the panel Mounting plate installation To install the mounting plate do the following 1 Separate the mounting plate from the touchpad by first loosening the screw then lift the touchpad away from the mounting plate see Figure 1 Figure 1 Mounting plate screw Table 1 Touchpad power usage Current mA Conditions 75 Maximum alarm current with the buzzer sounding and the touc...

Страница 6: ...rovided Note Do not overtighten screws or the mounting plate may bind and prevent the touchpad from mounting properly 5 For wall mount installations cut a hole in the wall behind the mounting plate to pull the wiring cable through Wiring the touchpad to the panel To wire the touchpad to the panel do the following 1 Remove panel AC and backup battery power 2 Run a 4 conductor 18 to 22 gauge wire fr...

Страница 7: ... to install systems with no alphanumeric touchpads we recommend that you keep an alphanumeric touchpad with you specifically for installer programming This touchpad can be quickly connected and disconnected from the header pins on the lower left portion of the panel just above the terminal strip To power up the panel and verify bus communication 1 Verify that all wiring between the panel and touch...

Страница 8: ...e 11111111111 AAAAAAAAAAA etc Pressing displays Es and pressing displays Fs After about 15 seconds of no touchpad activity the touchpad returns to the time display Test system operation Testing the system operation requires you to perform some standard operations to ensure that they work properly To test the system s operation do the following Arm disarm the system activate the touchpad panics byp...

Страница 9: ...brightness To adjust display background brightness do the following 1 Enter user programming mode by pressing 9 system master code The display shows SYSTEM MENU then TIME dATE 2 Press A or B until the display shows OPTIONS then press The display shows dOWnLd ON 3 Press A or B until the display shows BRIgHT 2 default setting 4 Enter a setting from 0 LEDs off to 3 brightest then press The display sh...

Страница 10: ...sing the default frequency during or within 15 seconds of any button activity at that specific touchpad Change status tone pitch To change the status tone pitch do the following 1 Press and hold the and 0 buttons together until you hear a steady tone then release the buttons 2 Press and hold 1 to lower the pitch or press and hold 2 to raise the pitch 3 Release the button when the desired pitch is ...

Страница 11: ...al business hours Monday through Friday excluding holidays between 6 a m and 5 p m Pacific Time Note Be ready at the equipment before calling for technical support Online publication library Another great resource for assistance with your GE Security products is our online publication library available to all of our customers on our website To access our publication library go to our website at th...

Страница 12: ...tenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician help Table 4 Specifications Specification Rating Compatibility Concord Concord Express Concord Ultra Concord 4 Power requirements 12 VDC nominal 75 mA Temperature range 32 to ...

Отзывы: