![GE Evolve R150 Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/ge/evolve-r150-series/evolve-r150-series_instructions_129681002.webp)
bottoming occurs) past “snug position’’. This should be done one turn
at a time alternating in pattern according to Figure 1.
WARNING: UNDER NO CONDITIONS SHOULD BOLTS BE TORQUED
TO A LEvEL GREATER THAN 12 FOOT-POUNDS.
Figure 1
CAUTION
Risk of injury
•
LED light source achieves full intensity immediately
upon being powered on.
Do not look directly at LED light source while
energized.
WIRING
NOTE: Make all electrical connections in accordance with the
National Electrical Code and any applicable local code requirements
including grounding.
NOTE: Verify that supply voltage is correct by comparing it to
nameplate.
Terminals are readily accessible on terminal board and will accept
service leads ranging in size from AWG No. 16 through NO. 6.
Service leads (See fixture labeling for supply wire temperature
rating) should extend through mounting bracket approximately
7 inches. Attach service leads to terminal board as shown
on luminaire nameplate. See table below for screw torques.
A wiring diagram is provided on a label in luminaire.
PHOTOELECTRIC CONTROL
When used, photoelectric (PE) receptacle should be oriented so that
the word “North” is directed toward true north. This is done by seating
a PE control into receptacle, lifting upward on PE control (which will lift
PE receptacle also), and rotating them clockwise until word “North”
is directed toward true north. Then lower PE control and receptacle
to firmly seat them into position. No tools are required to make this
adjustment.
Alternatively, PE receptacle can be oriented before PE control is
installed. This is done by lifting up on rim of the PE receptacle and
rotating it until the word “North” is directed toward true north. Lower
PE receptacle to firmly seat it in this position. Then install PE control.
FINAL ASSEMBLY POWER MODULE DOOR
To replace door, hold it at an angle of approximately 35 degrees from
vertical and toward pole side of hinge. Carefully insert hinge pin into
hinge and allow door to hang free. Note that door is mechanically
interlocked with top housing in all positions except in the vicinity of
removal location. All units: The doors are designed to be assembled
to top housing while in upright position with gravity holding hinge
pin properly in the cradle. If door is to be assembled to top housing
while lying on its back, extreme care should be taken to ensure that
hinge pin is properly engaged in the cradle by lifting up rear of door.
Otherwise, breakage may occur.
MAINTENANCE
In order to maintain high efficiency of reflectors and refractors, a
regular cleaning cycle should be established with frequency dependent
on local conditions. Use a mild soap or detergent which is essentially
neutral (follow manufacturer’s recommendation; pH approximately
6 to 8), nonabrasive, and which contains no chlorinated or aromatic
hydrocarbons. Wash outside thoroughly, using a soft cloth, or brush if
necessary. Rinse in clean, cold water and wipe dry.
STORAGE
Prior to installation, units should NOT be stored outside in corrugated
boxes (cardboard boxes) alone.
Until installation, all units should be placed in a covered dry storage
area. The storage area should not exceed -40°C (-40°F) to
50°C (122°F).
1. This can be preferably in a roofed area or
2. This can be done with a tarp that is secured in such a way to keep
water off of the corrugated boxes (cardboard boxes).
Terminal Board Torque Table
Wire Range Copper
Aluminum
Torque
(AWG)
(in lbs)
10 - 16 SOL, STR
30
8 - 6 SOL, STR
6 SOL, STR
45