• To maintain high efficiency of the lens, occasional

cleaning of the outer lens surface may be needed,

with frequency dependant on local conditions.

• Use a mild soap or detergent, which is essentially

neutral pH (pH approximately 6 to 8), non abrasive,

and which contains no chlorinated or aromatic

hydrocarbons.

• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.

ACCESS DOOR

3

MAINTENANCE / CLEANING

4

FIGURE 1

Set screw
(4 places)

  Rotate globe

• With power disconnected, open access door  and

disconnect the LED driver connector.

• Remove globe by rotating counter-clockwise

approximately 90° and raising off locking ring

(see 

Figure 1

).

Do not rotate by the lens

• Replace globe by lowering into locking ring and

rotating 90° clockwise.

• Verify that orientation of globe is correct.  For proper

orientation, see “street/house side” label on globes.

Orientation of the globe may be changed by

loosening tenon set screws and rotating in desired

direction.

• Install set screws (found in pack) for tamper resistant

or 2G applications.

• Reconnect LED driver connector inside base and

replace door.

MOUNTING

1

WARNING

Risk of injury or damage.

  Unit will fall if not installed 

 properly.  Follow installation instructions.

• Place unit on 3-inch diameter x 3-inch long tenon

(76mm x 76mm).

• Torque set screws to 10-12 ft-lbs. (14-16 N-m).

GLOBE REMOVAL / INSTALLATION

2

WARNING

Risk of electric shock.

  Make certain power is off before 

attempting any maintenance.

• Access to terminal board, fusing and photo control

(PE option 2, 3 or 4) is through the access door (

Figure 2

).

• Unscrew access door screws and pull door forward

to open.

• Connect input power leads to terminal block.

• Replace ignitor, fuses and photo control with same

type and rating.

• Close door until locked.

WARNING

Risk of injury.

  LED light source achieves full intensity 

 immediately upon being powered on. Do not look 

directly at LED light source while energized during install.

Loosen thumb screws 

to access terminal 

board and PE 

receptacle

FIGURE 2

PE location

(PE option 2, 3 or 4)

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in 

connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not 

covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting.

g

GE Lighting • 1-888-MY-GE-LED 

(1 - 888 - 69 - 43 - 533)

 • www.gelighting.com

GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

Содержание Evolve Avery StreetDreams EPAS

Страница 1: ...he limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to ra...

Страница 2: ...6mm x 76mm Torque set screws to 10 12 ft lbs 14 16 N m GLOBE REMOVAL INSTALLATION 2 WARNING Risk of electric shock Make certain power is off before attempting any maintenance Access to terminal board fusing and photo control PE option 2 3 or 4 is through the access door Figure 2 Unscrew access door screws and pull door forward to open Connect input power leads to terminal block Replace ignitor fus...

Страница 3: ... appareil est conforme aux exigences de la partie 15 des règles de la FCC Son utilisation est sujette aux conditions suivantes 1 cet appareil ne doit pas causer d interférences nuisibles 2 cet appareil doit accepter toutes les interférences reçues y compris celles pouvant causer un fonctionnement indésirable Cet équipement d éclairage classe A est conforme à la norme canadienne ICES 005 A NMB 005 ...

Страница 4: ...s et à la commande photo électrique Option PE 2 3 ou 4 se fait par la trappe d accès voir la Figure 2 Dévisser les vis de la trappe d accès et tirer la trappe vers l avant pour ouvrir Brancher les fils d alimentation à la borne électrique Remettre en place l allumage les fusibles et le contrôle photoélectrique avec des pièces du même type et de même classification Fermer la trappe d accès Desserre...

Отзывы: