Euro Simon Security System
37
•
CHIME Doors-Press to enable two beeps that sound from interior sirens, panel siren, and
the X-10 powerhorn siren (if set to unit number 9) when a protected door or window
learned into sensor group 10 or 13 is opened. If Option 41: Chime Voice is on, the panel
speaker also announces the sensor name and number.
•
CHIME Special Motion- Press to enable three beeps that sound from interior sirens, panel
siren, and the X-10 powerhorn siren (if set to unit number 9) when a Motion Sensor that is
programmed as sensor type 25 is activated. If there are no sensors learned into sensor group
25, this function will not be available. If Option 41: Chime Voice is on, the panel speaker
also announces the sensor name and number.
•
LIGHTS Time Activated-Press to enable system controlled lights to turn on/off at a sched-
uled time.
•
LIGHTS Sensor Activated-Press to enable system controlled lights to turn on for 4 minutes
when a specific sensor is tripped.
•
AUX, POLICE, FIRE-Press and hold or press twice quickly to activate a non-medical,
police, or fire emergency alarm
Sensor Testing
We recommend that you test the sensors after all programming is completed and whenever a
sensor-related problem occurs.
Note
While the sensor test is a
valuable installation and ser-
vice tool, it only tests sensor
operation for the current
conditions. You should per-
form a sensor test after any
change in environment,
equipment, or programming.
1. Place all sensors in their secured (non-alarm) state.
2. Open the panel cover.
3. Enter the appropriate access code.
4. Press Test.
The panel responds with Sensor test, press again to change or DONE to select.
5. Press DONE. The panel prompts you to trip each sensor one at a time. You may follow the
panel voice prompting or test the sensors in any order. Use the “Sensor Tripping Instruc-
tions” table on the next page.
Note
If a sensor does not meet
the minimum transmission
beep requirements, refer to
the “If a Sensor Fails the
Sensor Test” section of this
manual
6. Interior sirens and speakers sound transmission beeps and a voice announcement identifies
the tripped sensor. Each beep represents one RF packet. Count the number of beeps and
refer to the “Minimum Beeps” table for minimum requirements. After the beeps, the panel
announces, Sensor Name is activated, sensor status is XX (XX = number of RF packets).
The system will continue to prompt for sensors that have not yet been tested. When all sen-
sors have been tested the panel will announce, Sensor test complete, press DONE.
Sensor Tripping Instructions
Sensor
Do This
Door/Window
Open the secured door or window
Freeze
Apply ice to the sensor. Do not allow the sensor to get wet
Water
Press a wet rag or wet finger over both of the round, gold-plated ter-
minals on the underside of the sensor
Glass Guard
Tap the glass 7 to 10 cm from the sensor
Motion Sensor
Avoid the Motion Sensor field of view for 5 minutes, then enter its
view
Rate-of-Rise Heat
Detector
Rub your hands together until warm, then place one hand on the
detector for 30 seconds
Shock
Tap the glass twice, away from the sensor. Wait at least 30 seconds
before testing again
Smoke
Press and hold the test button until the system sounds transmission
beeps
Panic Buttons
Press and hold the appropriate panic button(s) for 3 seconds
KeyChain Touchpad
Press and hold LOCK and UNLOCK simultaneously for 3 seconds
Remote Handheld
Touchpad
Press and hold the 2 EMERGENCY buttons simultaneously for 3 sec-
onds