![GE ESS22 Series Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/ge/ess22-series/ess22-series_technical-service-manual_131461049.webp)
– 47 –
Compressor Not Running
Unplug refrigerator
Warm freezer thermistor to 70 F
Connect power and set temperature
controls to 5 and 5.
Is the compressor running?
Adjust settings and allow
24 hours to stabilize
Yes
Check for 120VAC at connector J7-9
orange wire to TERMINAL-J8 black wire.
Do you have 120VAC?
Replace
compressor
Yes
No
Check wiring to
compressor,
overload & relay
Yes
Replace main board
No
No
Direct test the
compressor.
Did it start?