51
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
13 Exposure Calculator
Here it is possible to enter or select the exposure factors by which the
mA x min - product
must be multiplied in order to adapt the exposure time, related to a D7 film, or the correction
factors in order to convert various materials to the common exposure diagrams for steel
and aluminum.
Press the
F4
key to toggle between the
masks.
Use the
F2
key to change the keypad arrangement.
NOTE:
To compensate differing conditions in the unit or film development set-up,
the correction factors for the standard materials Fe, Al and Ti can also be
changed
Use the arrow keys
and
or
and
to select the respective parameter. Via the numeric
keypad it is possible to enter values for the corresponding
Film
and
Material
parameters.
Press the
F4
key to accept the entry.
Press the
F3
key to call the default values stored in the unit: