Par. No. #
Parameter description
Default value
4-set-up
Change during
operation
Conver-
sion index
Type
T-04
Occurrence
[0] All days
2 set-ups
TRUE
-
Uint8
T-08
Timed Actions Mode
[0] Timed Actions Auto
2 set-ups
TRUE
-
Uint8
T-09
Timed Actions Reactivation
[1] Enabled
2 set-ups
TRUE
-
Uint8
T-1#
T-10
Maintenance Item
[1] Motor bearings
1 set-up
TRUE
-
Uint8
T-11
Maintenance Action
[1] Lubricate
1 set-up
TRUE
-
Uint8
T-12
Maintenance Time Base
[0] Disabled
1 set-up
TRUE
-
Uint8
T-13
Maintenance Time Interval
1 h
1 set-up
TRUE
74
Uint32
T-14
Maintenance Date and Time
ExpressionLimit
1 set-up
TRUE
0
TimeOfDay
T-15
Reset Maintenance Word
[0] Do not reset
All set-ups
TRUE
-
Uint8
T-16
Maintenance Text
0 N/A
1 set-up
TRUE
0
VisStr[20]
T-5#
T-50
Energy Log Resolution
[5] Last 24 Hours
2 set-ups
TRUE
-
Uint8
T-51
Period Start
ExpressionLimit
2 set-ups
TRUE
0
TimeOfDay
T-53
Energy Log
0 N/A
All set-ups
TRUE
0
Uint32
T-54
Reset Energy Log
[0] Do not reset
All set-ups
TRUE
-
Uint8
T-6#
T-60
Trend Variable
[2] Frequency [Hz]
2 set-ups
TRUE
-
Uint8
T-61
Continuous Bin Data
0 N/A
All set-ups
TRUE
0
Uint32
T-62
Timed Bin Data
0 N/A
All set-ups
TRUE
0
Uint32
T-63
Timed Period Start
ExpressionLimit
2 set-ups
TRUE
0
TimeOfDay
T-64
Timed Period Stop
ExpressionLimit
2 set-ups
TRUE
0
TimeOfDay
T-65
Minimum Bin Value
ExpressionLimit
2 set-ups
TRUE
0
Uint8
T-66
Reset Continuous Bin Data
[0] Do not reset
All set-ups
TRUE
-
Uint8
T-67
Reset Timed Bin Data
[0] Do not reset
All set-ups
TRUE
-
Uint8
T-8#
T-80
Power Reference Factor
100 %
2 set-ups
TRUE
0
Uint8
T-81
Energy Cost
1 N/A
2 set-ups
TRUE
-2
Uint32
T-82
Investment
0 N/A
2 set-ups
TRUE
0
Uint32
T-83
Energy Savings
0 kWh
All set-ups
TRUE
75
Int32
T-84
Cost Savings
0 N/A
All set-ups
TRUE
0
Int32
5.1.23 CL-## PID Closed Loop
Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
CL-0#
CL-00
Feedback 1 Source
[2] Analog Input 54
All set-ups
TRUE
-
Uint8
CL-01
Feedback 1 Conversion
[0] Linear
All set-ups
FALSE
-
Uint8
CL-02
Feedback 1 Source Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
CL-03
Feedback 2 Source
[0] No function
All set-ups
TRUE
-
Uint8
CL-04
Feedback 2 Conversion
[0] Linear
All set-ups
FALSE
-
Uint8
CL-05
Feedback 2 Source Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
CL-06
Feedback 3 Source
[0] No function
All set-ups
TRUE
-
Uint8
CL-07
Feedback 3 Conversion
[0] Linear
All set-ups
FALSE
-
Uint8
CL-08
Feedback 3 Source Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
CL-1#
CL-12
Reference/Feedback Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
CL-13
Minimum Reference/Feedb.
0 ProcessCtrlUnit
All set-ups
TRUE
-3
Int32
CL-14
Maximum Reference/Feedb.
100 ProcessCtrlUnit
All set-ups
TRUE
-3
Int32
CL-2#
Parameter Lists
AF-600 FP
™
Programming Guide
DET-620D
03/2016 All rights reserved.
229
5
5