Installation Instructions

4

5

 ELECTRICAL CONNECTION 
INFORMATION

ELECTRICAL REQUIREMENTS

This appliance must be supplied with 120V, 60Hz, and 

connected to a properly grounded branch circuit, 

protected by a 15- or 20- amp circuit breaker or time- 

delay fuse. If electrical supply provided does not meet the 

above specifications, it is recommended that a licensed 

electrician install an approved outlet.

    WARNING - 

TO REDUCE THE 

RISK OF FIRE, ELECTRICAL SHOCK, 

AND PERSONAL INJURY:

• DO NOT USE AN EXTENSION CORD OR AN ADAPTER 

PLUG WITH THIS APPLIANCE.

Dryer must be electrically grounded in accordance 

with local codes and ordinances, or in the absence 

of local codes, in accordance with the NATIONAL 

ELECTRICAL CODE, ANSI/NFPA NO. 70.

    WARNING -

 

THIS DRYER IS 

EQUIPPED A THREE-PRONG (GROUNDING) 

PLUG FOR YOUR PROTECTION AGAINST 

SHOCK HAZARD AND SHOULD BE PLUGGED 

DIRECTLY INTO A PROPERLY GROUNDED 

THREE-PRONG RECEPTACLE. DO NOT CUT 

OR REMOVE THE GROUNDING PRONG FROM 

THIS PLUG.

ENSURE PROPER GROUND EXISTS BEFORE USE.

IF LOCAL CODES PERMIT,

AN EXTERNAL GROUND WIRE

(NOT PROVIDED), WHICH MEETS

LOCAL CODES, MAY BE ADDED

BY ATTACHING TO THE GREEN

GROUND SCREW ON THE REAR

OF THE DRYER, AND TO A GROUNDED

METAL COLD WATER PIPE OR OTHER

ESTABLISHED GROUND.

6

 EXHAUST INFORMATION

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

• Terminate in a manner to prevent back drafts or entry of birds 

or other wildlife.

• Termination should present minimal resistance to the exhaust 

air flow and should require little or no maintenance to prevent 

clogging.

Never install a screen in or over the exhaust duct. This could 

cause lint build up.

• Wall caps must be installed at least 12 in. above ground level 

or any other obstruction with the opening pointed down.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4 ft. of 

straight duct, including distance between last turn and exhaust 

hood.

TURNS OTHER THAN 90º

• One turn of 45º or less may be ignored.

• Two 45º turns should be treated as one 90º turn.

• Each turn over 45º should be treated as one 90º turn.

SEALING OF JOINTS

• All joints should be tight to avoid leaks. The male end of each 

section of duct must point away from the dryer.

• Do not assemble the ductwork with fasteners that extend into 

the duct. They will serve as a collection point for lint.

• Duct joints can be made air and moisture-tight by wrapping 

the overlapped joints with duct tape.

• Horizontal runs should slope down toward the outdoors ½inch 

per foot

INSULATION

Duct work that runs through an unheated area or is near air 

conditioning should be insulated to reduce condensation and 

lint build-up.

    WARNING -

 

IN CANADA AND IN THE 

UNITED STATES, THE REQUIRED EXHAUST DUCT 

DIAMETER IS 4 IN (102mm). DO NOT USE DUCT 

LONGER THAN SPECIFIED IN THE EXHAUST 

LENGTH TABLE.

Using exhaust longer than specified length will:

• Increase the drying times and the energy cost.

• Reduce the dryer life.

• Accumulate lint, creating a potential fire hazard.

The correct exhaust installation is YOUR RESPONSIBILITY. 

Problems due to incorrect installation are not covered by 

the warranty.
Remove and discard existing plastic or metal foil transition 

duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of

bends of the exhaust system depends upon the type of duct, 

number of turns, the type of exhaust hood (wall cap), and all 

conditions noted below. The maximum duct length for rigid 

metal duct is shown in the table below.

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

90 Feet

60 Feet

45 Feet

35 Feet

0

1

2

3

60 Feet

45 Feet

35 Feet

25 Feet

25 Feet

4

15 Feet

Use only for short

run installations

Содержание DuraDrum GTDX200GM

Страница 1: ...all 1 800 GECARES US or Visit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future...

Страница 2: ...ation of the plugged tapping Supply line is to be 1 2 in rigid pipe and equipped with an accessible shut off within 6 ft of and in the same room with the dryer Use pipe thread sealer compound or Teflon tape appropri ate for natural or LP gas You must use with this dryer a flexible metal connector listed connector ANSI Z21 24 CSA 6 10 The length of the connect shall not exceed 3 ft Connect flexible...

Страница 3: ...nd thread sealant Caution Use adapters as shown Connector nuts must not be connected directly to pipe threads WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS FLARE NPT PIPE SIZE Listed connector ANSI Z21 24 CSA 6 10 1 8 NPT PIPE PLUG FOR CHECKING GAS INLET PRESSURE AT LEAST 1 2 3 8 NPT TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WR...

Страница 4: ...t performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90º One turn of 45º or less may be ignored Two 45º turns should be treated as one 90º turn Each turn over 45º should be treated as one 90º turn SEALING OF JOINTS All joints should be tight to avoid leaks The male end of each section of duct must point away from ...

Страница 5: ...int creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creatin...

Страница 6: ...to the exhaust pipe with the other clamp ELBOWSHIGHLY RECOMMENDED ELBOWHIGHLY RECOMMENDED DO DONOT SITD RYER ONFLEXIBLE EXHAUS T DONOTUSE EXCESSIVE EXHAUST LENGTH DONOT CRUSH FLEXIBLE EXHAUST AGAINST WALL DON T 9 ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See...

Страница 7: ...int Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct CAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow Cut the duct as shown and keep portion A 9 A B FIXING HOLE Through the rear opening locate the tab in the...

Страница 8: ...ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ROTATE DOO...

Страница 9: ...and until firmly seated 4 Insert the filter screen in the coupling of the washer s inlet hose If a rubber flat washer is already in place remove it before installing the filter screen Attach this coupling to one male end of the Y connector Tighten by hand until firmly seated 5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to the other male end of the Y connector ...

Отзывы: