MDS 05-4670A01, Rev. E
SD Series Reference Manual (x710 Mode)
54
NOTE:
If a firmware installation fails, the radio is left with the original
active image intact, and the inactive image will be unusable.
Reprogramming should be attempted again.
Error Messages During File Transfers
It is possible to encounter errors during a file transfer. In most cases
errors can be quickly corrected by referring to Table 16.
Table 16. Common Errors During TFTP Transfer
Error Message
Likely Cause/Corrective Action
Invalid File Type
Indicates that the file is not a valid firmware
file. Locate proper file and re-load.
File not found
Invalid or non-existent filename on TFTP
server
Invalid file path
Invalid or non-existent file path to TFTP server
Timeout
TFTP transfer time expired. Increase the
timeout value.
Bad CRC
Cyclic Redundancy Check reporting a
corrupted file. Attempt to re-load, or use a
different file.
Version String Mismatch
Invalid file detected. Attempt to re-load, or use
a different file.