Содержание DNCD450EG8WC

Страница 1: ...These conditions will obstruct dryer airflow and increase the risk of fire Do not install or store this appliance in any location where it could be exposed to water and or weather Save these instructions Installers Be sure to leave these instructions with the customer NOTE Installation and service of this drger requires basic mechanical and electrical skills It is gour responsibilitg to contact a ...

Страница 2: ...grounding terminal on the appliance CONNECTING DRYER USING 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION NOTE Since January 1 1996 the National Electric code requires that the new constructions utilize a 4 wire con nection to an electric dryer WARNING Onlg a 4 conductor cord shall be used when the appli ance is instolled in a location where grounding through the neutral conductor is ...

Страница 3: ...TED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4in 102ram DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EX HAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not cover...

Страница 4: ...reen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shal...

Страница 5: ...SIVE DO NOT _ AGAINST WALL _ For best drging performence 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with u clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe ...

Страница 6: ...ion information 19IGARAGE INSTALLATION IF ALLOWED BY LOCAL CODES Dryers installed in garages must be elevated 18 inches 46cm above the floor I1 O1DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET WARNING BEFOREPERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVE...

Страница 7: ...afety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST PLATE KIT WE1M454 Connect stondord metol elbows ond ducts to complete the exhuust system Cover bock opening with o plote Kit WE1M454 ovoiloble from your Iocol service provider Ploce dryer in finol Iocotion _WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE KIT WEIM454 I_CHANGING DIRECTION OF DOOR OPENING OPTIONAL 1 Op...

Страница 8: ...CE HALF WAY MOVE THE DOOR INAND DOWN UNTIL SECURE EACH HINGE AT THE THE TOP HINGE AND THE BOTTOM HINGEBOTTOM AND TIGHTEN THE TWO ARE RESTING ONTHE TOP SCREWS TOP SREWS OFEACH HINGE INSERTED INSTEP 1 SERVICING _WARN ING LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INSTALLATION REGISTER YOUR NEW APPLIANCE TO R...