background image

READ THOROUGHLY BEFORE INSTALLING

GENERAL

This luminaire is designed for outdoor lighting applications, and should not be used in areas of limited

ventilation, or in high ambient temperature enclosures; it should be installed and maintained according to

following recommendations.

UNPACKING

This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect

to confirm.

INSTALLATION

Reflector Rotation: Reflectors may be rotated such that socket is in any of four positions. This allows for

variations in beam aiming. In order to rotate the reflector the following procedure should be followed.
1.

Rotation is best accomplished before mounting the luminaire on pole.

2.

Note the rear edge of reflector position with respect to hinges (edge inserted into hinge pocket). Access

reflector by loosening reflector plate to main housing screw and allowing reflector plate assembly to lie on

door assembly. It is not necessary to detach tether.

3.

Remove four screws which attach reflector to reflector plate.

4.

Rotate reflector to desired position, being careful not to twist socket lead wires.

5.

Reattach reflector by reinserting four screws.

6.

Reposition reflector plate by inserting rear edge of plate into hinge pocket and attach plate to main housing

with screw.

MOUNTING

CAUTION

Unit will fall if not installed properly

Follow installation instructions

WARNING

Risk of electric shock

Turn power off before servicing

see instructions

CAUTION

Risk of burn

Allow lamp/fixture to cool before handling

NOTE:

 Power leads should be pulled as mounting parts are assembled, verifying that leads are free and not

pinched. Ballast voltage selection is best accomplished before mounting luminaire. See 

Wiring

 for instruc-

tion.

A. ARCHITECTURAL MOUNTING: (Arm)

1.

Install nut plate inside pre-drilled pole with nuts to inside. Secure with screw provided.

2.

Install the two (2) studs insuring that they fully penetrate the nuts on the nut plate.

3.

Align the upper and lower guides on the inside of the mounting arm with their respective studs and slide it

into place against the pole.

4.

Open luminaire door by pushing inward on latches while supporting door. Release reflector plate by loosening

plate main housing screw and allow plate to hang from tether.

5.

Install the luminaire and secure with flat washers and locknuts provided. Align the system as the nuts are

tightened.

CAUTION: Ensure that nuts fully engage the two studs. Correct tightening of stud nuts

is important to ensure proper function of mounting system. Torque to 18 - 22 foot pounds.

B. OTHER MOUNTINGS

External Slipfitters, Knuckle Flat Surface, Knuckle Pole Top and Round Pole Adapters are

also available for use with housings machined with a diagonal hole pattern. Installation is similar

to the Architectural Mounting.

CAUTION: Do not mount any unit below or greater than 60° above horizontal.

LAMP INSTALLATION

Use only lamps specified on nameplate. Observe lamp manufacturer’s recommendations and

restrictions on lamp operation, particularly ballast type, burning position, etc.

LAMP TIGHTNESS — 

The lamp should be securely inserted to NEMA-EEI specified torque of 35 inch-pounds,

which is best achieved by very firmly tightening to insure application of sufficient torque. Tightening must be

sufficient to fully depress and load center contact of socket.

WIRING:

Make all electrical connections in accordance with the National Electrical Code and any applicable local code

requirements.

GEH-5823A

INSTRUCTIONS

Decashield

®

 1000 DSA (Arm)

Verify that supply voltage is correct by comparing it to nameplate.

If unit is designated as multivolt or multiwatt, follow specific instruction.

Do not remove insulated connectors from wires not needed for required voltage connection.

Connect supply leads to internal terminal board as shown on wiring tag.

NOTE:

 Terminal board will accept supply leads ranging in size from AWG No. 14 through No. 6 (check

nameplate for minimum temperature requirement and electrical data).

IF SINGLE VOLTAGE:

All single voltage ballasts are pre-wired such that user need only connect the supply conductors.

IF MULTIVOLT: 

(120/208/240/277 volts)

Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the

ballast terminal nameplate.

IF MULTIWATT:

Multiwatt ballasts are available in various combinations of wattage. See wiring instructions on wiring tag

inside the luminaire. Reattach reflector plate, close door and check for secure latch engagement.

Installation is complete.

PHOTOELECTRIC CONTROL (if option present)

Photoelectric control receptacle should be oriented before control is installed. Loosen the two holding

screws and rotate receptacle until “North’ is directed as near as possible to true North. Tighten holding screws

and install control.

MAINTENANCE AND CLEANING

It will occasionally be necessary to clean outside of door glass to maintain light levels. Frequency of cleaning

will depend on ambient dirt levels and minimum light level which is acceptable to user. Door glass should be

washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and

wiped dry. Should the optical assembly become dirty on inside, wipe reflector and clean door glass in above

manner, and replace any damaged gasket.

The light output of a luminaire is also dependent on age of lamp. In applications where light levels are critical

it may be desirable to replace lamps before they burn out. Lamp manufacturer can provide data showing how lamp

light output decreases with use.