background image

Specification Revised 1/08

360451

Best Performance

Maximum Length  

of 4" Dia.  

Rigid Metal Duct

Maximum Length  

of 4" Dia.  

Flexible Metal Duct

Number

of

90°

Turns

Exhaust Hood Type

Exhaust Hood Type

A

4" Opening

B

2-1/2" 

Opening

A

4" Opening

B

2-1/2" 

Opening

Front Loading 
Dryers

0
1
2
3
4

90 ft.
60 ft.
45 ft.
35 ft.
25 ft.

60 ft.
45 ft.
35 ft.
25 ft.
15 ft.

55 ft.
40 ft.
30 ft.
20 ft.
15 ft.

45 ft.
30 ft.
20 ft.
15 ft.
10 ft.

A

B

2-1/2

4

GE Dryer Vent

Dryer Exhausting Information – Metal Duct Only

For complete information, see installation instructions packed with your dryer.

Ducting Materials: For best performance, this dryer should be vented with 4” diameter all 
rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” 
venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the  
  side or bottom of dryer, add one turn.
2.  The maximum length of 4’  rigid (aluminum or galvanized) duct which can be tolerated is  
  shown in the table. The maximum length for flexible ducts are less than for rigid duct.
  A turn of 45° or less may be ignored. Two 45° turns within the duct length should be  
  treated as a 90° elbow. 
  A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts 
of moisture and lint from being blown into the room. Gas dryers or any dryer located in a 
closet 

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed 
house floor (crawl space), or into an attic, since the accumulated lint could create a fire 
hazard or moisture could cause damage. Never terminate the exhaust into a common duct 
or plenum with a kitchen exhaust, since the combination of lint and grease could create a 
fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird 
nesting, etc. The wall cap must also be located at least 12" above the ground or any other 
obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are 
equivalent to a 4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE-CARES.

DCVH640EJ 

GE

®

 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer

 

Listed by 

Underwriters 

Laboratories

Содержание DCVH640EJ

Страница 1: ...cuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer 27 1 5 8 41 1 2 31 1 8 5 1 2 3 3 4 Electr...

Страница 2: ...set doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to t...

Страница 3: ...le ducts are less than for rigid duct A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room Gas dryers or any dryer located in a closet must be exhausted to the outsi...

Страница 4: ...ng inside for easy loading and unloading Quiet By Design Engineered for quiet operation Adjustable End of Cycle Signal Alerts you when cycle is done saving time between loads Multiple Dry Cycles Deliver optimal drying results Antibacterial Option Certified by the NSF to reduce up to 99 9 of certain types of bacteria 5 Heat Selections Offer enhanced drying performance and fabric care DuraDrum Provi...