Countdown display.
(DMCD models only)
GEAppliances.com
The countdown display shows the remaining operating time as well as the current drying cycle.
The display board is configured for a 45-minute dry time at the factory to correspond with
the 45-minute timer cam pre-installed in the coin box. If the timer cam is modified for another
operating duration, the dip switches on the display board should be set as follows:
NOTE:
This display does not accumulate time. See the following examples of display possibilities.
DIP SWITCH NUMBERS
DRYING TIME (minutes)
1
2
45
1
1
60
1
0
90
0
1
120
0
0
DIP SWITCH SETTING (min)
COIN SLIDE ACTUATIONS
DISPLAY READING (min)
45
1
45 to 0, then blank
45
2
45 to 1, then 1 for next 45 min.,
then 0 and blank
120
1
99 for 21 minutes, then 98 to 0,
then
blank