Electrical Connections

NOTE: 

Do not use connectors pre-filled with silicone grease/mineral base protective grease or use silicone grease to seal connections.

Red stripe (+)

White (-)

Connect LED strips using in-line (IDC) connectors or 

twist-on wire connectors.
NOTE: 

Seal all connections in wet locations with 

electrical grade RTV silicone.

1

Cap wires

Optional:

 Cut wires flush

Must cap all exposed wires with appropriate wire 

connectors and seal with electrical grade RTV silicone. 

Optional: 

Cut wires flush to the module and seal with 

electrical grade RTV silicone.

2

Connect the red stripe wire (+) of the LED strip to the red 

wire (+) of the power supply.  Connect the white wire (-) 

of the LED strip to the black or blue wire (-) of the LED 

power supply.
NOTE:

  All electrical connections should be suitably 

protected from mechanical damage and the 

environment. Seal all connections in wet locations with 

electrical grade RTV silicone.

4

Run a wire from the LED power supply to the LED module 

and connect. 
NOTE:

 Must be used with Tetra® 24 Volt Power Supplies.

NOTE:

 Refer to Maximum Loading & Remote Mounting 

Specifications

 on page 4.

3

LED 

Power 

Supply

To Tetra LED System

Red (+)

Black or blue (-)

To LED 

power 

supply 

Red (+)

Black or 

blue (-)

Red Stripe (+)

White (-)

Seal all connections in wet locations 

with electrical grade RTV silicone

Seal all connections in wet locations 

with electrical grade RTV silicone

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a 

current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less). 

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated 

transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.  NOTE: Follow all federal and local regulations 

when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or 

country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a 

metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.

5.   (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.  Follow 

the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount 

the module.  Before installing, ensure the surface is dry.

6.  Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7.  A Tetra

®

 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the 

Tetra

®

 Class 2 Power Supply chosen.

8.  Follow the instructions above to properly mount the LED modules. 
9.  Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the 

power supply installation guide.

11.  If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

Содержание Current Tetra miniMax

Страница 1: ...u Canada WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before inspection installation or removal Properly ground GE power supply enclosure RISK OF FIRE Use only UL approved wire for input output connections Minimum size 18 AWG 0 82mm2 Follow all NEC and local codes Not to be submerged or used in a marine environment RISK OF FIRE OR ELECTRIC SHOCK LED Retrofit Kit installation require...

Страница 2: ...e hole for supply wire access 5 6 Remove all the debris from the inside of the channel letter and replace the sign face NOTE For halo lit applications LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting ...

Страница 3: ...ment to be replaced such as neon tubing or fluorescent tubes and associated transformers and ballasts Care should be taken not to break the existing neon or fluorescent tubes NOTE Follow all federal and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disconnect switch as r...

Страница 4: ...LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting for the Tetra LED system A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to keep water from collecting on the Tetra LED strip These products are not required to be en...

Отзывы: