Dimension Information (in inches) 

Hood Exhaust Duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION
The hood exhaust has been designed to mate with a standard 3-1/4” x 10” 
rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. 
Do not use less than a 6” diameter duct.

REAR EXHAUST
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust 
with the space between studs, or wall should be prepared at the time it is constructed 
by leaving enough space between the wall studs to accommodate exhaust.

MAXIMUM DUCT LENGTH
For satisfactory air movement, the total duct length of 
3-1/4” x 10” rectangular or 6” diameter round duct should 
not exceed 140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., 
present additional resistance to airflow and are equivalent 
to a section of straight duct which is longer than their 
actual physical size. When calculating the total duct length, 
add the equivalent length of all transitions and adaptors plus 
the length of all straight duct sections. The chart below 
shows the approximate feet of equivalent length of some 
typical ducts.

Listed by 

Underwriters 

Laboratories

Grille

Filter Kit Accessory

Filter Kit
JX81D–Recirculating 
Charcoal Filter Kit
To be used when  
the Advantium oven  
cannot be vented  
to the outside.

Duct 

Equivalent

A.  Rectangular-To-Round 

5 Ft. 

  Transition Adaptor
B.  Wall Cap 

40 Ft.

C.  90° Round Elbow 

10 Ft.

D. 45° Round Elbow 

5 Ft.

E.  90° Rectangular Elbow 

25 Ft.

F.  45° Rectangular Elbow 

5 Ft.

G. Roof Cap 

24 Ft.