Chapter 3: Programming
Concord 4 Installation Manual
47
Security - partition 1 to 6 settings
Account number
Shortcut: 0010 to 0060
Default: 00000
The account number is used as panel (or customer) identification for the
central monitoring station. The panel sends the account number every time
it reports to the central station. Account numbers must be 1 to 10
characters long.
Alpha characters A to F can be assigned to the account number by pressing
and holding buttons 1 to 6 respectively, until the character appears.
When using the CID reporting format, the letter A is reported as a 0.
Quick arm
Shortcut: 0011 to 0061
Default: Off
This feature allows system arming without using an access code. When
quick arm is on, the system arming level can be increased from off to stay,
from off to away, or from stay to away, without entering an access code. A
valid access code is still required to decrease the arming level or disarm the
system.
Quick exit
Shortcut: 0012 to 0062
Default: On
This feature determines whether or not users can open and close a
standard entry/exit door without causing an alarm (while the system is
armed). This feature also allows you to leave the armed premises without
having to disarm and rearm the system. When this feature is on, pressing D
on a touchpad (while the system is armed) starts a two-minute timer that
allows one standard entry/exit door (sensor groups 10 and 19 only) to be
activated once (opened, then closed). When this feature is off, you must
disarm the system before any protected door is opened.
Exit extension
Shortcut: 0013 to 0063
Default: On
This feature determines whether you can reenter and exit again through an
entry or exit delay door (without disarming and rearming the system). This
helps prevent exit faults and false alarms by allowing you to reenter the
premises for a forgotten item.
When this feature is on, the panel restarts the exit delay timer if you reenter
the premises through a standard delay door before the standard exit delay
time expires. When this feature is off, the exit delay timer does not restart if
you reenter the premises, forcing you to disarm the system to avoid setting
off an accidental alarm.
Keyswitch sensor
Shortcut: 0014 to 0064
Default: None
This feature lets you arm and disarm the system using either a keyswitch
wired to a hardwired zone input or a wireless door/window sensor (sensor
01 to 96).
Note:
We recommend you program (learn) keyswitch sensors into group 28.
For example, if sensor 1 is designated as the keyswitch sensor and the
system is disarmed, then tripping sensor 1 could arm the system to Away. If
the system is armed to Stay or Away, then tripping the sensor could disarm
the system (depending on keyswitch style).
The panel reports opening, closing, and force-armed reports (if turned on) to
the central monitoring station.