C-RS Ultrasonic Flow Transducer Installation Guide
39
6.9 Mounting Transducers into the MCF (cont.)
3.
On one of the transducers, apply a thin bead of couplant down the center of its face approximately the size of a
toothpaste bead.
Note:
To prevent the loss of couplant, do not slide the transducer with couplant along the surface of the pipe when
mounting.
4.
Place the two transducers into the blocks. Make sure the junction box faces away from the mounting block as
shown below.
Note:
If the transducer cables are already connected to the flowmeter, you must identify the upstream and
downstream cables and connect them to the appropriate transducers.
Couplant
Line
Top of Pipe