background image

Features

• Long life 
• 3 years warranty 
• IP20: Dry location rated
• Class I indoor recessed luminaire

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Light source type

CMH 20W/35W G8.5 lamps. For lamp designation,
see control gear.
For best performance use GE ConstantColor

TM

 CMH light 

source.

Save These Instructions

Use only in the manner intended by the manufacturer. 
If you have any questions, contact the manufacturer.
 

Unit Installation 

• Prior to installation, isolate the mains supply.
• Carefully unpack unit from its packaging.
• Cut appropriate diameter circular hole at desired location 

for luminaire. 

(Diagram A)

• Remove reflector from luminaire and place in secure 

location, taking care not to damage reflector surface.

• Electrical termination to be carried out by qualified 

electrician in accordance with latest edition of IEC 60364.  
Diagram C: 3- core 230V AC mains cable supplied.  
1: Line-Brown 2: Earth-Yellow/Green 3: Neutral-Blue

• Offer luminaire up into desired location, ensuring there is 

the required minimum air space around the control gear 
housing.

 (Diagram B)

• Lock the luminaire into place by means of the two 

adjustable fixing springs as detailed in 

Diagram E.  

Hold luminaire in position, and press downward at point 
indicated, until luminaire is fully secured. Check the 
mechanical stability of the luminaire. Confirm with ceiling 
manufacturer that ceiling tile can support luminaire weight.

• Carefully relocate reflector into luminaire. (If reflector is 

vacuum metalised, use gloves.)

GE

Lighting

Installation Guide

• The luminaire shall only be used complete with its 

protective shield. Do not operate without the safety glass.

• Only to be installed outside arms reach.
• The luminaire is not suitable for covering with thermally 

insulating material. 

• For indoor use only.
• All install and uninstall shall be done by a certified 

electrician.

• If the external flexible cable or cord of this luminaire is 

damaged, it shall be replaced by the manufacturer or his 
service agent or similar qualified person in order to avoid a 
hazard.

RISK OF ELECTRIC SHOCK
• Do not operate luminaire with damaged parts.
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all local codes. 
• Use only appropriate IEC approved wire for connections, 

minimum size: 3x1 mm

2.

Warning

A

B

Cut out diameter: D= 110 mm
Ceiling thickness: min. 1 mm – max. 35 mm

C

D

GE CMH  

Downlight

 

GE CMH Fixed Downlight Range 3

1

2 3

L E N

L E N

210 mm

min 73 mm

115 mm

R = min 285 mm

210 mm

control gear