78
Group
Value
Displayed
Failure Code Definition
Setting Criteria
Door B
oa
rd
50
0
thru 59
9
F500
0 5 0 0
Can't reach Target Hot Water Temp.
Hot Water time limit expires and temperature not
reached.
F501
0 5 0 1
Flow meter Missing.
No pulses/flow meter signal during Dispense.
F502
0 5 0 2
Flow meter pulsing with no water dispensing.
Wait 1 minute after a dispense is over before running
this diagnostic
F503
0 5 0 3
Ice/water stops dispensing based on time (7 Minute
Timeout).
If the Dispense stops due to timeout
F504
0 5 0 4
Can't Fill Hot water Tank
Hot water fill time expires without tripping the level
sensor.
F505
0 5 0 5
Overcurrent Flag1 Tripped
Ice Box Gasket Heater
F506
0 5 0 6
Overcurrent Flag2 Tripped
Recess, Mullion or Fill Tube Heater
F507
0 5 0 7
Cold Water Cup Switch Input missing
Cup Switch message is received and 30 seconds
later the Cup Switch input is still not present
F508
0 5 0 8
Cold Water Cup Switch Input present
Cup Switch input is present for 30 seconds and no
Cup Switch message has been received
F509
0 5 0 9
Hot Water Cup Switch Input missing
Hot Water message is received and 30 seconds later
the Cup Switch input is still not present
F510
0 5 1 0
Hot Water Cup Switch Input present
Cup Switch input is present for 30 seconds and no
Cup Switch message has been received
F511
0 5 1 1
Door board Ice Mold Temp Invalid.
F512
0 5 1 2
Door board Ice Box Invalid.
F513
0 5 1 3
Door board HotWater1 Thermistor Invalid.
Thermistor temps do not match
F514
0 5 1 4
Door board HotWater2 Thermistor Invalid.
F515 -
F599
0 5 1 6
– 0 5 9 9
Door Board for Future Expansion.
Door Board Failure Codes
Содержание CFE29TS
Страница 1: ...2013 CAFÉ French Door Refrigerator ...
Страница 2: ...CFE29TS CYE23TS PYE23PS PYE23KS 2013 CAFÉ and Built in Style French Door Refrigerator ...
Страница 7: ...7 ...
Страница 9: ...9 Odor Filter ...
Страница 11: ...11 Other Odor Filter Screens ...
Страница 16: ...16 Deli Drawer ...
Страница 17: ...17 Deli Control Turned Off ...
Страница 18: ...18 Deli Control Meat Selected ...
Страница 19: ...19 Deli Control Beverage Selected ...
Страница 20: ...20 Deli Control Produce Selected ...
Страница 21: ...21 Deli Control Cheese Selected ...
Страница 22: ...22 Deli Control Citrus Selected ...
Страница 26: ...Main Board Deli Connectors on Schematic DELI PAN BOARD DELI PAN FAN DELI PAN THERMISTOR DELI PAN DAMPER ...
Страница 27: ...27 Hot Water System ...
Страница 28: ...28 ...
Страница 32: ...32 HOT WATER OPTIONS ...
Страница 39: ...39 HOT WATER IS READY ...
Страница 44: ...44 Isolation Valve ...
Страница 46: ...46 Hot Water Tank and Water Valve ...
Страница 51: ...51 ...
Страница 54: ...Main Control Board ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 Control Panel On Board Diagnostics ...
Страница 61: ...61 Service Diagnostics Press and hold Water Crushed Cubed Pads together for 3 seconds to enter Service Mode ...
Страница 67: ...67 Service Diagnostics Tests ...
Страница 82: ...82 This concludes the presentation Thanks for your attention ...