Installation Preparation–Electrical Supply

PREPARE ELECTRICAL WIRING

The improper connection of the equipment
grounding conductor can result in a risk 
of electric shock. Check with a qualified 
electrician or service representative if you 
are in doubt that the appliance is properly 
grounded.

For models equipped with power cord:

 Do not modify the plug 

provided with the appliance; if it will not fit the outlet, have a 
proper outlet installed by a qualified technician.

Cabinet Preparation and Wire Routing

• The wiring may enter the opening from either side, rear 

or the fl oor within the shaded area dimensioned in Figure A 
and illustrated above.

• Cut a 1-1/2" max. diameter hole to admit the electrical cable. 

Cable direct connections may pass through the same hole 
as the drain hose and hot water line, if convenient. If cabinet 
wall is metal, the hole edge must be covered with a bushing.

Note:

 Power cords with plug must pass through a separate 

hole.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.
• For cable direct connections the cable must be routed as 

shown in Figure E. Cable must extend a minimum of 24" 
from the rear wall.

• For power cord connections, install a 3-prong grounding 

type receptacle in the adjacent cabinet rear wall, 6" min. 
or 18" max. from the opening, 6" to 18" above the fl oor. 
The receptacle must be accessible and therefore cannot 
be installed in the back wall of the dishwasher enclosure.

5

Figure E

WARNING

Electrical Requirements

• This appliance must be supplied with 120V, 60Hz., and 

connected to an individual properly grounded branch circuit  
protected by a 15- or 20-ampere circuit breaker or time-
delay fuse.

• Wiring must be 2 wire with ground and rated for 75°C (176°F).
• If the electrical supply does not meet the above 

requirements, call a licensed electrician before proceeding.

Grounding Instructions–Permanent Connection

This appliance must be connected to a grounded-metal, 
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment-grounding terminal or lead on 
the appliance.

Grounding Instructions–Power Cord Models

This appliance must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This appliance is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is installed and 
grounded in accordance with all local codes and ordinances.

ADVERTENCIA

La conexión incorrecta del conductor de 
conexión a tierra del equipo puede resultar 
en choque eléctrico. Consulte con un 
electricista calificado o representante 
de servicio si tiene dudas de la conexión 
a tierra del aparato.

WARNING

FOR PERSONAL SAFETY: Remove house fuse 
or open circuit breaker before beginning 
installation. Do not use an extension cord or 
adapter plug with this appliance.

ADVERTENCIA

PARA SEGURIDAD PERSONAL: Retire el 
fusible de la casa o abra el interruptor de 
circuitos antes de empezar la instalación. 
No use un cable de extensión o enchufe 
adaptador con este aparato.

Содержание CDWT980RSS - Cafe 24" Tall Tub Dishwasher

Страница 1: ...CONTROLS PRESS HEATED DRY FOR 3 SECONDS ENHANCE MENTS SELECTIO NS SENSING WASHING RINSING DRYING SANITIZED CLEAN COOK WARE NORMAL WASH SPEED CYCLE CHINA CRYSTAL RINSE ONLY 2 4 8 DELAY HOURS ADDED HEA...

Страница 2: ...ply Thread seal tape UL listed wire nuts 3 Materials For New Installations Only Air gap for drain hose if required Waste tee for house plumbing if applicable Electrical cable or power cord if applicab...

Страница 3: ...asher at a later date for service if needed Special consideration for a dishwasher installed on a elevated platform The elevated platform must be flat and level Cabinets Square and Plumb Floor MUST be...

Страница 4: ...local codes or ordinances require an air gap Is waste tee less than 18 above the oor If the answer to either question is yes an air gap must be used Refer to Method 1 Figure C in the adjacent illustra...

Страница 5: ...e 5 Figure E WARNING Electrical Requirements This appliance must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit break...

Страница 6: ...ter connection is on the bottom left side of the dishwasher Install the hot water inlet line using 3 8 or larger copper tubing Route the line as shown in Figure F and extend forward at least 19 from r...

Страница 7: ...e This Mounting Hole After adjusting spring tension open and close the door to make sure the door operates smoothly If the door is hard to move or if the spring cable binds check the routing of the sp...

Страница 8: ...manently connected to the house electrical system In this step you will need the junction box cover and the 10 x 1 2 hex head screw from the screw kit set aside in Step 1 The power cord and connection...

Страница 9: ...nt drain hose damage and possible leaks Be careful not to nick or cut the drain hose Push the end of the drain hose over the drain pump outlet being careful not to disturb the check valve Refer to Fig...

Страница 10: ...ishwasher will fit in the cabinet Check to be sure the power cable drain hose and hot water line are not trapped behind the dishwasher Utility lines trapped behind the dishwasher prevent the dishwashe...

Страница 11: ...e Step 14 until the door moves freely and does not contact the cabinet frame Figure U Figure V Countertop Controls Hidden by Countertop TIME REMAINING Special Considerations for Positioning Top Mount...

Страница 12: ...hould t in the tub opening without hitting the side of the tub If the racks roll on their own or the door hits the side of the tub relevel the dishwasher IMPORTANT After leveling verify that the dishw...

Страница 13: ...E LENGTH MUST NOT EXCEED 10 FOR PROPER DRAIN OPERATION DRAIN LINE INSTALLATION Connect drain line to air gap waste tee or disposer using the previously determined method Secure the drain hose to the a...

Страница 14: ...halfway Check to be sure it does not roll back or forward on the door If the rack moves adjust leveling legs See Step 14 Check door alignment with cabinet If door hits cabinet reposition or relevel d...

Страница 15: ...o be sure disposer plug has been removed and or air gap is clear See Step 17 Also check drain line to be sure it is not kinked Run the dishwasher through another Rinse Only cycle Check for leaks and c...

Страница 16: ...tallation STEP 23 INSTALL TOEKICK Locate toekick and screws set aside in step 5 Replace the toekick and make sure it is against the oor Insert and tighten the 2 toekick attachment screws The toekick s...

Страница 17: ...respecter tous les codes et r glements Remarque pour l installateur Il faut prendre soin de laisser ces instructions pour le client et l inspecteur local Remarque pour le consommateur Il faut garder c...

Страница 18: ...de tuyau vis Dispositif de r duction de tension pour les branchements lectriques Robinet Conduite d eau en cuivre de 3 8 po minimum Manchon de raccord pour rallonger le tuyau de vidange le cas ch ant...

Страница 19: ...forme La plate forme doit tre plane et niveau Figure B Il faut installer le lave vaisselle moins de 3 m 10 pi de l vier pour que l coulement soit ad quat Le lave vaisselle doit tre enti rement enclos...

Страница 20: ...anger correctement et de s endommager si le raccord de vidange n est pas la bonne hauteur avec un dispositif anti siphon ou une boucle de vidange lev e d au moins 81 cm 32 po Pr paration pour l instal...

Страница 21: ...dessus du sol La prise doit tre accessible et de ce fait ne doit pas tre mont e sur la paroi arri re de l enceinte du lave vaisselle 5 Figure E Alimentation lectrique Cet appareil doit avoir une alime...

Страница 22: ...par les codes locaux La conduite d eau se branche au c t gauche inf rieur du lave vaisselle Installer la conduite d alimentation d eau chaude avec un tuyau en cuivre de minimum 9 mm 3 8 po Acheminer l...

Страница 23: ...un des trois trous du c ble de la poulie Figure I Augmenter la tension Diminuer la tension Utiliser ce trou de montage 05A 1183P Apr s avoir ajust la tension du ressort ouvrir et fermer la porte pour...

Страница 24: ...i le lave vaisselle doit tre branch de mani re permanente sur le circuit lectrique de la maison cette tape trouver le couvercle de la bo te de jonction et la vis n 10 de 1 2 po t te six pans mis de c...

Страница 25: ...c la vis de collier situ e au bas du tuyau IMPORTANT Pr venir tous dommages au tuyau de vidange et les fuites ventuelles Prendre soin de ne pas entailler ou couper le tuyau de vidange Placer l extr mi...

Страница 26: ...yau de vidange et le tuyau d alimentation d eau chaude ne se trouvent pas coinc s derri re le lave vaisselle Tout tuyau ou fil coinc derri re le lave vaisselle emp che l encastrement complet du lave v...

Страница 27: ...pas en contact avec le cadre de l armoire Figure U Figure V Plan de travail Commandes cach es par le plan de travail TIME REMAINING 05A 1183Y Points consid rer pendant le placement de mod les command...

Страница 28: ...oire Ils ne doivent pas bouger Ouvrir et fermer la porte La porte doit recouvrir l ouverture du bac sans toucher les c t s Remettre le lave vaisselle niveau si les gouttoirs se d placent de leur propr...

Страница 29: ...TION DU TUYAU DE VIDANGE Brancher le tuyau de vidange sur le dispositif anti siphon le raccord en t d gout ou le broyeur d chets en utilisant la m thode indiqu e pr c demment Monter avec des colliers...

Страница 30: ...e par rapport au bac et que le lave vaisselle est de niveau Consulter l tape 14 Sortir l gouttoir du bas moiti chemin V rifier qu il ne recule ni n avance Si l gouttoir se d place r gler les pieds de...

Страница 31: ...du lave vaisselle et v rifier que la plus grande partie de l eau s est coul e Si ce n est pas le cas v rifier que le bouchon du broyeur a t enlev et ou que le dispositif anti siphon est libre de d br...

Страница 32: ...A PLINTHE Prendre la plinthe et les vis rang s l tape 5 Remettre la plinthe en place en v rifiant que le bord inf rieur se trouve contre le sol Serrer les deux vis de fixation de plinthe La plinthe do...

Отзывы: