![GE CDT835SxJ0 Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ge/cdt835sxj0-series/cdt835sxj0-series_technical-service-manual_125523011.webp)
– 11 –
Target Temperatures
Exposed Heater Target / Max Temperature Limits
Cycle
PW4
MW
PR1
FR
Rinse
Express
120
135
135
140
Light
125
130
135
eWash
120
125
Normal
125
140
Auto
130
140
Heavy
130
135
130
145
Hidden Heater Target / Max Temperature Limits
Cycle
PW4
MW
PR1
FR
FR w/Dry
Rinse
Express
120
135
135
140
160
Light
125
130
135
135
eWash
120
125
125
Normal
125
140
160
Auto
130
140
160
Heavy
130
135
130
145
160
7DUJHWWHPSHUDWXUHVDUHVHWLQWKHFRQWUROWRDFKLHYHSHDNSHUIRUPDQFH3URSHUWHPSHUDWXUHFDQEHDȺHFWHG
by low temperature incoming water, heater not operational, and installation. The dishwasher will achieve
these goals if the above considerations are true.
Содержание CDT835SxJ0 Series
Страница 60: ... 60 Diagnostics Strip Circuit ...
Страница 90: ... 90 Schematics CDT835SxJ0xx PDT825SxJ0xx and PDT835SxJ0xx ...
Страница 91: ... 91 CDT835SxJ0xx PDT825SxJ0xx and PDT825SxJ0xx ...
Страница 92: ... 92 ZDT915SxJ0xx and ZDT915SxJ0xx ...