GEH-5304A
8
B.
Mounting
Motors and generators should be mounted on rigid and solid foundations. Level the base (or the machine).
Hold-down bolts should be inspected regularly and kept tight. The feet of the machine may be doweled to
the foundation plates or base when alignment procedures are completed. Sliding bases, when used, should
be securely anchored to the foundation.
Motors are mechanically suitable for mounting with shaft horizontal or vertical on floor, ceiling or sidewall.
When sidewall or ceiling mounted, special provisions must be made to maintain the integrity of dripproof
enclosures.
When motor is sidewall or ceiling mounted, lifting points in addition to the
standard lifting lugs may be required. Lifting, in these cases should be done by
experienced riggers to avoid injury to personnel and damage to the motor.
C.
Alignment
Be sure to align or check alignment carefully on either motors or motor genera-
tor sets. Misalignment can cause excessive vibration and damaging forces on
shafts and bearings.
Time taken to assure good alignment will be returned in reduced downtime.
1.
Coupled Drive
When a motor is used to drive a unit, flexible couplings must be used to facilitate alignment. Three-
bearing construction requires a rigid coupling.
Careful alignment of machines when using either solid (rigid) or flexible cou-
plings is essential to prevent excessive vibration and bearing or shaft failures.
D
$OLJQPHQW3URFHGXUH
)OH[LEOH&RXSOLQJ1RQ6HOI6XSSRUWLQJ%DVHV
Before grouting the base, the coupling should be checked as follows:
1.
Slide the sleeve from the coupling so that the hub faces are exposed.
2.
Check that the coupling hub spacing is in accordance with the outline dimensions with
the units in the mechanical center of their end play.
3.
Check parallel alignment by using a straightedge across the hubs at both vertical and
horizontal locations, or by clamping a dial indicator to one hub and indicating the other
hub on its outside diameter. Be sure that the dial indicator supports do not bend or sag,
since this will give inaccurate readings.
4.
Use a dial indicator at hub faces and rotate both units together 90
°
, 180
°
, 270
°
and 360
°
or measure the gap at each position by inserting a feeler gage. The reading should not
vary more than 0.002”.
5.
Correct any vertical misalignment by shimming between the base and the foundation.
Содержание CD2512AT
Страница 26: ...GEH 5304A 26 ues ...
Страница 34: ...GEH 5304A 34 Figure 3 Application Information for CD2512AT CD2813AT Frames ...
Страница 35: ...GEH 5304A 35 Figure 4 Blower Unit Commutator End Mounted for Use With CD2512AT CD2813AT Frames ...
Страница 36: ...GEH 5304A 36 Figure 5 Dimensions Air Openings for CD2512AT CD2813AT Frames ...
Страница 38: ...GEH 5304A 38 Figure 6 Accessory Mounting CD2512AT CD2813AT ...
Страница 39: ...GEH 5304A 39 Figure 7 Accessory Mounting CD2512AT CD2813AT ...
Страница 40: ...GEH 5304A 40 ...
Страница 41: ...GEH 5304A 41 Type CD Frames 2512AT 2813AT DC Motors Generators Figure 8 Type CD Frames 2512AT 2813AT ...
Страница 43: ...GEH 5304A 43 Detach and fax or mail to the address noted above ...