Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Indications for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Scanning Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

General Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Caring for the Transducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Service and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Cleaning and Disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Starting Scanning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Connecting the Transducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Changing Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Using a Transducer Cover  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Changing Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Holding the Transducer for Intraoperative Scanning  . . . . . . . . . . . . . . . . . . . . . . 8
Puncture Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Single-Use Needle Guide UA1336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sterile Needle Guide UA1336 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Assembling the Needle Guide and Mounting it on the Transducer . . . . . . . 11
Releasing the Needle During Biopsy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Performing Puncture and Biopsy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
RF and Microwave Ablation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleaning after Puncture and Biopsy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

English source version

 

BB1312-

N

Содержание BK MEDICAL 8815 Series

Страница 1: ...English BB1312 N April 2023 For Professional Users Only Intraoperative Transducer User Guide Type 8815...

Страница 2: ...nd services As part of our customer satisfaction program we contact a sample of our customers a few months after they receive their orders If you receive an email message from us asking for your feedb...

Страница 3: ...ing a Transducer Cover 7 Changing Orientation 8 Holding the Transducer for Intraoperative Scanning 8 Puncture Facilities 8 Single Use Needle Guide UA1336 9 Sterile Needle Guide UA1336 10 Assembling th...

Страница 4: ...4...

Страница 5: ...diatric application suitable for ultrasound guided interventional procedures Needle guide UA1336 provides guidance for needles or other interventional devices during an ultrasound guided procedure UA1...

Страница 6: ...methods that the transducer can withstand are listed in the Product Data sheet Sterile cover is available See the Product Data sheet for more details WARNING If at any time the scanner malfunctions o...

Страница 7: ...transducer should be enclosed in a transducer cover or a standard condom See the Product Data sheet for a list of available transducer covers Note Sterile disposable sheaths are recommended for intrao...

Страница 8: ...osition which is comfortable for your hand and move the transducer smoothly over the surface of the organ to produce the best screen image Figure 3 Holding 8815 for scanning Puncture Facilities Intrao...

Страница 9: ...angle Figure 5 Two needle guide insert palettes supplied together with needle guide UA1336 The 3 angle inserts each contain three channels These channels allow the needle to be positioned at 25 45 or...

Страница 10: ...iscarded after use The sterile packed needle guides must be stored at a temperature range from 15 C 57 F to 25 C 77 F and at a storage humidity of 30 to 80 Please refer to Care Cleaning and Safety for...

Страница 11: ...haped channel in the needle guide and slide the insert into the channel in the needle guide from above until it clicks into place and aligns with the needle guide Taking care not to damage the transdu...

Страница 12: ...dot on the screen WARNING If the needle guide is detached from the transducer during interventional procedures cover the transducer with a new transducer cover before reattaching the needle guide WARN...

Страница 13: ...disinfection and sterilization processes may not be effective Therefore you must clean transducers immediately after use Use a suitable brush to make sure that biological material and gel are removed...

Страница 14: ...14 April 2023 8815 User Guide BB1312 N...

Страница 15: ......

Страница 16: ......

Отзывы: