TROUBLESHOOTING TIPS
Error Codes
Electronic Control Error Code Diagnostics and Test Mode
Error Code Diagnostics
7KH6398HOHFWURQLFFRQWUROFRQWLQXRXVO\PRQLWRUVWKHXQLWRSHUDWLRQDQGZLOOVWRUHHUURUFRGHVLIFHUWDLQ
FRQGLWLRQVDUHZLWQHVVHG,QVRPHFDVHVWKHXQLWPD\WDNHDFWLRQDQGVKXWWKHXQLWRIIXQWLOFRQGLWLRQVDUH
corrected.
7RDFFHVVWKHHUURUFRGHPHQXSUHVVWKH³(17(5´EXWWRQ,IHUURUFRGHVDUHSUHVHQWWKH\ZLOOEHGLVSOD\HG,I
PXOWLSOHFRGHVH[LVW\RXFDQWRJJOHEHWZHHQHUURUFRGHVXVLQJWKH³6&52//´EXWWRQ7RFOHDUDOOFRGHVSUHVV
WKH³(17(5´DQG³6&52//´EXWWRQVIRUWKUHHVHFRQGVZKLOHLQWKHHUURUFRGHPRGH
Error Codes and Alarm Status
Unit Control Panel
7KHGLVSOD\VKRZQEHORZKDVIRXUGLJLWV7KHOHIWWZR
GLJLWVLQGLFDWHWKHHUURUFRGHWRWKH2Q2IILFRQV
above these two digits indicate the current state of
WKHHUURUFRGH7KHULJKWWZRGLJLWVVKRZWKHKLVWRU\
FRXQWXSWRRIWKHDVVRFLDWHGHUURUFRGH7KH
display contains a maintenance icon (wrench) that will
illuminate to indicate when the unit needs maintenance.
Check Error Codes:
3UHVVWKH(17(5NH\WRDFWLYDWHWKHGLVSOD\
(DFKSUHVVRIWKHVFUROONH\GLVSOD\WKHQH[WHUURUFRGH
Clear History Counters:
3UHVVDQGKROGWKH(17(5NH\DQG6&52//.(<IRUDERXWVHFRQGV
Error
Code
Problem
Action
)URQWSDQHOEXWWRQVWXFNIRUPRUHWKDQVHFRQGV
&RQWLQXHWRPRQLWRUIRU³23(1´XQVWXFNVZLWFK'RQRWSURFHVVVZLWFKLQSXW
2
,QSXWYROWDJHRXWRIVSHFL¿FDWLRQ
Unit stops, open all relays until voltage is back within specs then resumes operation
3
,QGRRUWHPSHUDWXUHVHQVRULVRSHQRUVKRUWHG
Unit defaults to 75
°
)LQ&22/,1*RU
°
)LQ+($7,1*DQGZLOOFRQWLQXHWRRSHUDWH
,QGRRUFRLOWHPSHUDWXUHVHQVRULVRSHQRUVKRUWHG
7KHXQLW¶VFRQWUROERDUGGHIDXOWV
°
),WZLOORYHUULGHWKHVHQVRUDQGWKHXQLWZLOOFRQ
-
tinue to operate.
5
Outdoor coil temperature sensor is open or shorted
7KHXQLWGHIDXOWVWR
°
)RYHUULGLQJWKHVHQVRU7KHXQLWZLOOFRQWLQXHWRRSHUDWH8V
-
LQJ(OHFWULFKHDWLIDYDLO($7,1*,IQRWDYDLODEOHLW($73803LIWKH
outdoor temperature allows.
6
2XWGRRUFRLO!JUHDWHUWKDQ
°
F
7KHXQLWZLOOVKXWGRZQIRUPLQXWHVUHVXPHRSHUDWLRQIRUPLQXWHV,IWHVWIDLOV
times, the severity is increased and the unit operation is locked out.
7
,QGRRUFRLOOHVVWKDQ
°
F for 2 consecutive
minutes
7KHFRPSUHVVRUZLOOWXUQRILJK)DQVSHHGZLOOUXQ:KHQFRLOWHPSUHDFKHV
°
F the unit will resume operation after lockout time.
8
8QLWF\FOHV!JUHDWHUWKDQWLPHVSHUKRXU
7KHXQLWZLOOFRQWLQXHWRRSHUDWHDQGEHPRQLWRUHG
8QLWF\FOHVOHVVWKDQWLPHVSHUKRXU
7KHXQLWZLOOFRQWLQXHWRRSHUDWHDQGEHPRQLWRUHG
Room freeze protection
Only use if Electric Heat is available. Run High Speed and Electric Heat until room
WHPSHUDWXUHUHDFKHV
°
)7KHXQLWZLOOGLVSOD\³)5=´GXULQJRSHUDWLRQ/RJJHGRQO\
Wall stat problem or connection issue
7KHXQLWZLOOQRWRSHUDWH
Not applicable
Not applicable
High pressure limit switch is open
,IXVLQJLVFRROLQJRUKHDWSXPSLVRQVKXWGRZQFRPSUHVVRU5XQKLJKIDQXQWLOVZLWFK
FORVHVWKHQUHVXPHRSHUDWLRQ7KHWKLUGRFFXUUHQFHLQKRXUORFNVXQLWRXW$SSOLFDEOH
WR.XQLWRQO\
Not applicable
Not applicable
Heat pump error
,ILQGRRUFRLOWHPSHUDWXUHLVOHVVWKDQDPELHQWWHPSHUDWXUHIRUPLQXWHVWKHXQLWZLOOXVH
electric heat to satisfy the heating demand.
7HPSHUDWXUHEH\RQGRSHUDWLQJOLPLWV
2FFXUVLIWKHDPELHQWWHPSHUDWXUHUDQJHIDOOVEHORZ
°
)RUJUHDWHUWKDQ
°
)7KH
error code will remain on until the temperature reaches the operating range and then the
unit will return to normal operation.
(TXLSPHQWGRHVQ¶WPHHWPLQLPXPFRQ¿JXUDWLRQ
7KHFRPSUHVVRUPXVWEHHQDEOHGDQGKDYHDWOHDVWIDQVSHHGV
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
22
2XWGRRUFRLOWHPSHUDWXUH
°
F for 2 consecutive
minutes
Unit will use electric heat to satisfy heating demands until the temperature equals or
H[FHHGV
°
F. Applicable for the Heat Pump models only.
23
Frost protection
Until we run active defrost for a minimum of 6 minutes when Heat Pump run time is
JUHDWHUWKDQPLQXWHVDQGRXWGRRUFRLOWHPSHUDWXUHLV
°
F or less
Not applicable
Not applicable
ENTER
SCROLL
OFF ON
On/Off
Error State
Enter
Button
Error
Code
History
Counter
Maintenance
Required
,QGLFDWRU
Scroll
Button