GE AWGH08WWF Скачать руководство пользователя страница 4

4

49-5000854   Rev. 0

SAFETY

 INFORMA

TION

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third 
(ground) prong from the power cord. For personal safety, 
this appliance must be properly grounded.

  DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 
3-prong (grounding) plug which mates with a standard 
3-prong (grounding) wall outlet to minimize the possibility 
of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A 
test and reset button is provided on the plug case. The 
device should be tested on a periodic basis by first 
pressing the 

TEST

 button and then the 

RESET

 button 

while plugged into the outlet. If the 

TEST

 button does 

not trip or if the 

RESET

 button will not stay engaged, 

discontinue use of the air conditioner and contact a 
qualified service technician.

Have the wall outlet and circuit checked by a qualified 
electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your 
personal responsibility and obligation to have it replaced 
with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its 
own individual electrical outlet which has a voltage rating 
that matches the rating plate.

This provides the best performance and also prevents 
overloading house wiring circuits which could cause a 
fire hazard from overheated wires.

See the Installation Instructions, 

Electrical 

Requirements 

section for specific electrical connection 

requirements. 

IMPORTANT

NOTE:

This air conditioner is designed to be operated under condition as follows and performance may be reduced 

outside of these operating temperatures. 

For the seasons that the air conditioner is not in use, ensure to drain all water out of the unit. Failure to do so 
may cause unwanted freezing which can affect performance for the next appropriate season. See the Care and 
Cleaning, 

Draining The Unit

 section for more information on how to properly drain the unit. 

Cooling 
Operation

Outdoor Temp:

70-109

F/21-43

C (70-118

F/21-48

for special tropical models)

Indoor Temp:

70-90

F/21-32

C

Содержание AWGH08WWF

Страница 1: ...5000854 Rev 0 09 23 AWGH08WWF AWGH12WWF SAFETY INFORMATION 3 USING THE AIR CONDITIONER Controls 5 Remote Control 5 CARE AND CLEANING 7 INSTALLATION INSTRUCTIONS 8 WIFI SETUP 14 TROUBLESHOOTING TIPS 1...

Страница 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Страница 3: ...nce and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do n...

Страница 4: ...ectrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong...

Страница 5: ...in Cool Heat and Fan only settings Press the Sleep mode pad and its light will illuminate The fan indicator will stay at the same setting but the air conditioner will automatically change the Fan spe...

Страница 6: ...et to Auto for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature If the room needs more cooling or heating the fan speed will automati...

Страница 7: ...arm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it...

Страница 8: ...ces Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mech...

Страница 9: ...mote Control Top Mounting Rail may be installed already Foam Seal 3 8 Bracket Screws 6 1 Wood Screws 8 2 1 2 Flat Head Bolt and Lock Nut 2 A B C D DELAY MODE ON OFF SPEED TEMP TIME TEMP TIME PARTS INC...

Страница 10: ...talled without the side curtain panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet mu...

Страница 11: ...line Cut and apply weather strip to front edge of window frame Cut and apply weather strip to back edge of the window sill Cut and apply a weather strip to side of the curtain frame one on each side...

Страница 12: ...FDVH WR the window sill Drill pilot holes if necessary Bottom rail Top rail Window sash SILL About 1 Wood Screws 2 1 Wood Screws 6 INSTALL OUTER CASE IN WINDOW continues D Thread nut onto bolt then t...

Страница 13: ...ach the window lock bracket to the upper window with a type C screw to secure the window in place A B A Top of lower window sash B Foam seal Vinyl Wood 8 RETURN CHASSIS TO THE OUTER CASE A Once the ca...

Страница 14: ...is held in strict accordance with the GE Appliances Connected Data Privacy Policy Visit geappliances com privacy privacy_policy_connected to view this policy How it Works Download the GE Appliances Ap...

Страница 15: ...ns However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determine...

Страница 16: ...Airflow is restricted Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may In the Cool mode press the Decrease pad...

Страница 17: ...s noise by removing the subbase water plug Removing this plug will lower the Energy Efficiency of your until NOTE Do not drill hole in the base pan Troubleshooting Tips Before you call for service Sav...

Страница 18: ...18 49 5000854 Rev 0 NOTES Notes...

Страница 19: ...ecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Replacement of house f...

Страница 20: ...ts that are available while your warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extende...

Страница 21: ...os en una etiqueta en el costado del acondicionador de aire INSTRUCCIONES DE SEGURIDAD 3 USO DEL ACONDICIONADOR DE AIRE Controles 5 Controle Romoto 5 CUIDADO Y LIMPIEZA 7 INSTRUCCIONES DE INSTALACI N...

Страница 22: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Страница 23: ...LQ GH DVHJXUDU TXH no se juegue con el electrodom stico 1R XWLOLFH VX DFRQGLFLRQDGRU GH DLUH HQ XQD KDELWDFLyQ h meda tal como un ba o o lavadero O HOHFWURGRPpVWLFR VH GHEHUi JXDUGDU D ILQ GH HYLWDU T...

Страница 24: ...para asegurar que el enchufe est correctamente conectado a tierra En caso de contar con un tomacorriente de pared de 2 cables es su responsabilidad y obligaci n reemplazarlo por un tomacorriente de p...

Страница 25: ...FRQILJXUD OD XQLGDG SDUD TXH gradualmente cambie las configuraciones en un per odo GH KRUDV D ILQ GH SHUPLWLU FLHUWR LQFUHPHQWR GH eficiencia energ tica durante las horas de inactividad El modo Sleep...

Страница 26: ...ontrol Este acondicionador de aire cuenta con una funci n de panel de control de luces encendidas apagadas donde dichas luces se apagar n cuando no haya actividad en los controles por m s de un minuto...

Страница 27: ...producir n atascamientos y reducir n su funcionamiento Direcci n del Aire Uso del Acondicionador de Aire Cuidado y limpieza Parrilla y Caja Apague el acondicionador de aire y retire el enchufe del to...

Страница 28: ...FLQWD PpWULFD iSL 1LYHO Tijeras o cuchilla 7DODGUR EURFD GH Preguntas Visite nuestra p gina en la red en GEAppliances com REQUISITOS EL CTRICOS El modelo AWGH08WWF requiere 115 V 5 15P protegido con...

Страница 29: ...ontrol Remoto Riel de Montaje Superior HV SRVLEOH TXH D HVWp LQVWDODGR Sellador de Gomaespuma Tornillos de Soporte de Tornillos de Madera de Tornillo de Cabeza Plana de RQWUDWXHUFD A C PARTES INCLUIDA...

Страница 30: ...arse sin los paneles de acorde n para ajustarse a una ventana m s estrecha Ver las dimensiones de la abertura de la ventana Todas las partes de apoyo deben quedar totalmente aseguradas a alg n metal m...

Страница 31: ...los marcos Riel de montaje superior Riel de montaje inferior Ajustar la cortina en el marco 5 PREPARE LA VENTANA PARA LA INSTALACI N A Mida el ancho de la abertura de la ventana B Marque la l nea cen...

Страница 32: ...aga agujeros piloto Bottom rail Top rail Window sash SILL About 5 Tornillos de Madera de 1 Tornillos de 0DGHUD GH 6 INSTALE LA CAJA EXTERNA EN LA VENTANA D Enrosque la tuerca en el tornillo luego enro...

Страница 33: ...H TXH OD FDMD HVWp DGKHULGD GH IRUPD VHJXUD a la ventana vuelva a instalar el acondicionador de DLUH RV SHUVRQDV GHEHQ OHYDQWDU HO DFRQGLFLRQDGRU de aire y deslizar el mismo sobre la caja Aseg rese de...

Страница 34: ...HQ HVWULFWR FXPSOLPLHQWR FRQ OD 3ROtWLFD GH 3ULYDFLGDG GH DWRV GH RQH LyQ GH SSOLDQFHV 3DUD DFFHGHU D HVWD SROtWLFD visite geappliances com privacy privacy_policy_connected CONFIGURACI N WIFI C mo Fu...

Страница 35: ...una instalaci n en particular Si este equipo provoca interferencias perjudiciales para la recepci n de radio o televisi n lo que puede comprobar encendiendo y apagando el equipo se aconseja al usuario...

Страница 36: ...presione la tecla Reducci n El filtro de aire est sucio LPSLH HO ILOWUR FDGD GtDV SRU OR PHQRV 9HU OD VHFFLyQ GH Cuidado y limpieza La habitaci n podr a haber estado caliente Cuando el acondicionador...

Страница 37: ...GR DSDJDGR O DJXD VH DFXPXOD HQ OD EDQGHMD GXUDQWH GtDV OOXYLRVRV R FRQ PXFKD KXPHGDG O DJXD SRGUtD GHUUDPDUVH JRWHDU GHVGH HO lado externo de la unidad O YHQWLODGRU SRGUtD IXQFLRQDU DXQ VL HO FRPSUHV...

Страница 38: ...49 5000854 Rev 0 Notas NOTAS...

Страница 39: ...endedor minorista o instalador Usted es responsable de brindar instalaciones de conexi n el ctrica adecuadas DOOD GHO SURGXFWR FRPR UHVXOWDGR GH PRGLILFDFLRQHV VREUH el mismo o debido a un uso irrazon...

Страница 40: ...disponibles mientras su JDUDQWtD D Q HVWi YLJHQWH D SXHGH DGTXLULU HQ FXDOTXLHU PRPHQWR D WUDYpV GH QWHUQHW RV 6HUYLFLRV GH SSOLDQFHV D Q HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppliances com...

Отзывы: