(continued)
in Window
to 39” Wide
1. Open window. Locate and mark
centerline of window.
2. Screw leveling bolt in correct
3/8” threaded hold of support
channel. Depth of window sill
determine which 3/8” threaded
hole to use.
3. Place support channel over
centerline of window sill with end
against window stool. Mark window
sill through Locating Hole A in
support channel.
4. Move support channel away
from window stool until Mounting
Hole B is over the mark on the
window sill. Secure the support
channel by driving a Type B wood
screw into the window sill through
Mounting Hole B.
5. Adjust leveling bolt so curved
top of support channel is 1/4”
below the top of the window stool.
This downward tilt toward the
outside prevents water from
entering the room.
Caution: Do not drill a hole in the
base pan. Unit is designed to
operate with approximately 1/2” of
water in the base pan.
Center the air conditioner in the
window opening with the bottom
bar sitting behind the window stool.
Do not cover side louvers.
Window Stool
Window Sill
!
Mounting Hole B
/-
Locating Hole A
Support Channel
Type B Wood Screw
Leveling Bolt
‘\
Side Louvers
Sash Tracks
Locating
Hole B
Hole A
318”
Threaded
Holes
Bolt
Channel
Window Sill
OUTSIDE