Soft Starter Remote Keypad
2
/2
4
Synchronising the Keypad and the Starter
The DB9 cable can be connected/disconnected from the keypad while the starter is
running.
The first time a keypad is plugged into a starter, the
starter will copy its parameter settings to the keypad.
If the keypad has previously been used with a soft starter, the operator can select
whether to copy the parameters to the starter, or to copy the soft starter's parameter
settings into the keypad.
Select the required option using the
and
buttons. Press
ENTER
to proceed with the selection.
NOTE
If the parameter software version in the keypad is different from the
software version of the starter, only
will be available.
NOTE
While the keypad is synchronising, only the
ENTER
and
STOP
buttons are enabled.
5
Mounting Diagram
Drill four mounting holes for screws (one in each corner) and two holes for the DB9
connector.
NOTE
Image is not to scale.
62 mm
68 mm
13 mm
1
3
6
m
m
1
4
2
m
m
1
3
m
m
25 mm (x2)
4 mm (x4)
0
6
1
5
9
.C